iNSTallaTiON
Commissioning
WSP-2-DUO, WSG-2-DUO
| 13
10.4 Completing the installation
10.4.1 Installation on finished walls
f
f
Fit the casing door in reverse order to its removal.
10.4.2 Installation on unfinished walls
!
Material losses
incorrect installation can lead to flames and smoke
spreading through the supply duct in case of a fire.
f
f
Observe the fire regulations.
f
f
insulate the wall recess correctly.
f
f
Close off/plaster the wall recess.
D
00000
75
19
1
f
f
Place the frame on the casing for unfinished walls so that
the 4 fixing tabs are located on the screws. Tighten the
screws.
f
f
Fit the casing door in reverse order to its removal. Ensure
you insert the rebate of the casing door into the frame.
11. Commissioning
f
f
Check the pipework and connections for leaks.
f
f
Visually inspect the appliance for leaks.
f
f
Open the shut-off valves.
Venting the DHW pipework
f
f
Open a nearby DHW draw-off point until the pipework is
free from air.
Filling and venting the heating system
WARNING Electrocution
Protect the electronics of the integral instantaneous
water heater from escaping water.
f
f
Fill and vent the central heating system according to the
heat generator operating and installation instructions.
f
f
Open the thermostatic valves of the connected radiators.
f
f
Draw off hot water to make water flow through the heat
exchanger.
f
f
Open the air vent screw (see chapter "Settings") until
water runs out.
f
f
Bleed the connected radiators.
Checking/correcting the heating water flow rate for a
heating circuit with mixer
f
f
Ensure heat supply through the central heat generator.
The flow temperature should have reached the design
value for the network.
f
f
Set the temperature controller to the required flow tem-
perature at the control valve.
f
f
Switch on the pump.
f
f
Perform hydronic balancing of the underfloor heating
circuit at the heating circuit distributor according to the
design engineer's specifications.
f
f
Do not draw off any DHW while testing the heating water
flow rate. Make sure that all thermostatic valves and un-
derfloor heating control valves are fully open.
f
f
after balancing is complete, check the set flow tempera-
ture again.
Checking the appliance
f
f
Check the appliance function.