![STIEBEL ELTRON WSG-2-DUO Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/stiebel-eltron/wsg-2-duo/wsg-2-duo_administrators-manual-for-operation-and-installation_1376881011.webp)
ENGL
IS
H
iNSTallaTiON
installation
WSP-2-DUO, WSG-2-DUO
| 11
10. Installation
!
Material losses
Only use open-ended spanners of the right size to
tighten and release screw connections.
10.1 Appliance installation
f
f
Only install the appliance after all preparatory installation
work has been completed.
f
f
Select fixing materials in accordance with the wall con-
struction/condition. in case of non-load bearing masonry,
mount the appliance on a frame stand.
f
f
Existing installation ducts and casings for installation
on finished or unfinished walls, which are available as
installation options or accessories, can be used for wall
mounting.
10.1.1 Preparing for installation
f
f
Connect the appliance to a mounting rail – available as an
accessory – or to a heating circuit distributor. Ensure that
the tabs on the mounting rail or the heating circuit distrib-
utor engage in the recesses on the appliance.
f
f
Place the flat gasket between the union nuts on the ball
valves and the connection threads on the appliance.
f
f
Tighten the union nuts (for torque see chapter "Specifica-
tion / Dimensions and connections").
Note
alternatively, you can retrofit the appliance. To elim-
inate contamination or other problems associated
with construction sites, it is sufficient to install only
the mounting rail or heating circuit distributor during
the construction phase.
10.1.2 Installing the heating circuit distributor on
finished walls
installation dimensions:
184
373
684
15
D
00000
75
10
4
The installation dimension "373 mm" refers to the clearance
from the floor covering.
f
f
Mark out the positions of holes to be drilled for the appli-
ance on the wall (see chapter "Specification / Dimensions
and connections").
f
f
Mount the appliance on the wall using the enclosed rawl
plugs and screws.
f
f
Tighten the screw connection between the appliance
and the mounting rail or heating circuit distributor (for
torque, see chapter "Specification / Dimensions and
connections").
f
f
Connect the mounting rail or heating circuit distributor to
the pipework with flat gaskets.
10.1.3 Installing the casing for finished walls
Note
When positioning the heat interface unit, ensure that
the casing is flush with the finished floor.
150
370
557
118
102
15
D0000075184
D
00000
75
18
9
f
f
Guide the recesses in the casing for finished walls – availa-
ble as an installation option or accessory – into the hooks
at the side of the mounting plate for the appliance from
above.