14 45 00-5
iii. Manufacturer information
viii.
One-touch access to the
Settings screen
which
displays 5 options which allows management of :
i. Settings screen option (1): On this screen,
operators shall have the ability to change the
language displayed on the screen as well as the
units of measure for height and weight (imperial
or metric units).
ii. Settings screen option (2): On this screen,
operators shall have the ability to retract the
mechanical locks during raising for reduced
noise, as well as to set a restricted maximum
lifting height.
iii. Area to allow for future expansion
iv. Portal to the
Shop screen
: access to this screen
requires a PIN with details of the Shop Screen
provide below.
v. Portal to
Information screen
option: access to this
screen requires a PIN with details of the
Information Screen provide below.
ix.
One-touch access to the
Shop screen
options
(access to the
Shop screen
shall be generally provided to only
maintainers and system administrators). The shop configuration
screen shall allow manipulation of:
i.
Edit of owner’s details: on this screen shall be
the ability to edit the information displayed on
the Owner’s field.
x. Access to the
Information Screen,
which displays 9
options (access to the
Information screen
shall be generally
provided to only maintainers and system administrators). The
maintenance configuration screen shall allow manipulation of:
Screen 1
i.
Initiation of foot protection which guards
against a crushing hazard during lowering.
This safety system, when enabled, will stop
lowering as the column reaches 18 inches
above finished floor. At that time, the operator
is provided a chance to inspect and ensure that
there are no obstructions in the area of the
vehicle and lifts. After confirmation that the
vehicle and lift area is clear of obstructions, the
operator simply needs to retract the mechanical
safety locks again and compete the lowering
cycle to bring the lift completely to the floor.
ii.
Ability to disable height difference monitoring to
aid in trouble shooting. Once initiated, this
control system option allows the maintainer to
operate the lifting system outside normal safety
limits. This system is only for use by the lift
system maintainer during repair procedures.
This system option will automatically be
disabled and the control system returned to
default operating parameters after 10 minutes.
iii.
Ability to apply a set value to height monitoring
system to aid in troubleshooting. Once
initiated, this control system option substitutes