14 45 00-6
a fixed value for the height monitoring device in
a particular column. This system is only for
use by the lift system maintainer during repair
procedures. This system option will
automatically be disabled and the control
system returned to default operating
parameters after 2 minutes.
Screen 2
i.
Ability to select wireless operating channel to
minimize interference
ii.
Ability to view total lift system run time to
properly plan for lift system maintenance.
iii.
Ability to view individual column motor run time
to properly plan for lift system maintenance.
Screen 3 Area to allow for future expansion
Screen 4 (Safety Messages)-area to allow for future
expansion
Screen 5 (Maintenance Messages)-area to allow for
future expansion
Screen 6 (Back up and Restore)
I.
Ability to restore control system to default
settings
Screen 7 (Software Version)
I.
Ability to review system operating information
Screen 8
I.
Ability to establish column type
II.
Ability to establish motor type, VDC or VAC
III.
Ability to establish control system
communication protocol
IV.
Ability to enable or disable weight measuring
Screen 9 (Battery Settings)
i.
Ability to establish at what voltage the system
will display that the battery system is WEAK
ii.
Ability to establish at what voltage the system
will display that the battery system is EMPTY
c.
All control panels shall have automatic synchronization through the full
stoke of the hydraulic cylinder with a maximum tolerance of 2 inches
(50 mm). Control system will actively control hydraulic correction to
maintain level synchronization, unless a column deviates more than 2.4
inches (60 mm) inches from any other column, at which point all motion
halts.
d.
Each column shall be fitted with an individual analog height measuring
device. This height measuring device shall ensure that the height of
each column in the set remains synchronized at the height initiated by
the operator. The height measuring device shall also allow, through
single operation, that the operator can raise or lower any column to
alternate heights within the tolerances set by the ALI (Automotive Lift
Institute) in its manual entitled “
Lifting It Right”
.
e. The wireless communication system shall utilize mesh-style wireless
technology and be properly shielded from external interference in the
workshop.
f.
The mobile column lift battery charger shall operate at the following
voltages: 110VAC.
g.
Control panel shall be rated IP 65.
9.
Safety Devices:
a.
An independent and fail-safe mechanical locking system shall be