Wireless
Symbol
Description
Function
switched back on again. Height difference
monitoring can also be switched back on from this
screen. This setting is not stored in memory, so
height difference monitoring is always switched
on after the system has been switched off and on
again.
Height
monitoring
This option ensures that the value at the
potentiometer input is replaced by a constant
value. The column will function normally without
the height differences being corrected. This can
be used to check whether the potentiometers (for
height measurement) are working properly. Height
monitoring must then be disabled.
If the height differences between the columns
become larger during raising and lowering, there
may be problems in the hydraulic circuit or other
mechanical faults.
The screen shows the message
<Height
monitoring off>
. There is also an acoustic signal
when raising or lowering to alert the operator to
the fact that this service operation is active.
This setting stays active for 2 minutes and height
difference monitoring is then automatically
switched back on again. Height difference
monitoring can also be switched back on from this
screen. This setting is not stored in memory, so
height monitoring is always switched on after the
system has been switched off and on again
Содержание ST 1065-FWF
Страница 1: ...Mobile column lifts Wireless Service and Parts manual 2015 Stertil B V 38007815 B ...
Страница 109: ...Service and Parts manual Version B 109 Wireless 8 18 Hydraulic cylinder ST1075 ...
Страница 111: ...Service and Parts manual Version B 111 Wireless 8 19 Hydraulic cylinder ST1065 ST1085 ST1100 ...
Страница 123: ...Service and Parts manual Version B 123 Wireless 10 APPENDICES 10 1 Electrical connections fig 37 Electrical connections ...