6
| STERO SD1 LOW TEMP DISHWASHER
INSTALLATION
(continued)
Electrical and grounding connections must comply with the
applicable portions of the National Electrical Code and/or other
local electrical codes.
Plumbing connections must comply with applicable sanitary,
safety and plumbing codes. Drain and fill line configurations
vary, some methods are shown on this drawing.
70 3/4" MAX
HANDLE HEIGHT
P2
FLOOR
69"
OVERALL
HEIGHT
22"
11"
24 7/8"
75 7/16"
68 5/8"
57 9/16"
34"
16 7/8"
DOOR OPENING
12 1/2"
CHEMICAL
SUPPLY
CONTAINER
62 9/16"
20 1/2"
40 1/4" MIN
HANDLE HEIGHT
CL
CL
P1
E1
P2
66 7/16"
20 3/4"
2 1/8"
2 1/8"
7 1/2"
26 3/16"
28 3/4"
OVERALL
WIDTH
CL
CL
MODEL:
SD-1
D-950292
REV. A
CONNECTION INFORMATION
(*AFF - ABOVE FINISHED FLOOR)
LEGEND
E1 ELECTRICAL CONNECTION: 1/2" CONDUIT HOLE,
66-7/16" AFF.
P1 COMMON WATER CONNECTION: 120°F WATER MIN.
(RECOMMENDED 140°F); 3/4" FPT, 62-9/16" AFF.
P2 DRAIN: 2" NPT, 12-1/2" AFF
MISCELLANEOUS NOTES:
ALL DIMENSIONS TAKEN FROM FLOOR LINE MAY INCREASE
3/4" OR DECREASE 1/2" DEPENDING ON LEG ADJUSTMENT.
NET WEIGHT OF MACHINE: 210 LBS.
DOMESTIC SHIPPING WEIGHT: 235 LBS.
SIZE OF RACKS - 19-3/4" X 19-3/4"
3/4 H.P. MOTOR
PLUMBING NOTES:
WATER HAMMER ARRESTOR (MEETING ASSE-1010
STANDARD OR EQUIVALENT) TO BE SUPPLIED
(BY OTHERS) IN COMMON WATER SUPPLY LINE AT
SERVICE CONNECTION. RECOMMENDED WATER
HARDNESS TO BE 3 GRAINS OR LESS FOR BEST RESULTS.
ELECTRICAL CONNECTION
ELEC.
SPECS
RATED
AMPS
MINIMUM
SUPPLY CIRCUIT
CONDUCTOR
AMPACITY
MAXIMUM
OVERCURRENT
PROTECTIVE
DEVICE
120/60/1
14.0
20
20
P2
E1
P1
2 1/2"
3/8"
12 5/8"
13 5/8"
10 1/8"
4 1/2" MIN CLEARANCE
FROM CHAMBER FOR
STRAIGHT THRU OR
CORNER INSTALLATION
4 1/2" MIN CLEARANCE
TO TANK WALL FOR
CORNER INSTALLATION
WALL
WALL
CL
CL
5/16-18 SST TRUSS HD SCREW
5/16-18 SST HEX HD NUT
5/16-18 SST LOCKWASHER
TANK
30"
2" MAX.
9" MAX
10-1/2"
21"
±
1/8
21-3/4"
±
1/8
1-1/4"
5/8"
1-1/4"
ROLL
SUGGESTED TABLE
FABRICATION
30
°
USE SILICONE SEALER
BETWEEN TABLE AND
LIP OF TANK TO
PREVENT LEAKAGE