Power supply:                                    

 9V battery or 9V transformer

Recommended water pressure:      

0.5-8.0 bar (7-116 PSI)

                                                               With water pressure of more than 8 bars,
                                                               use a pressure reducing valve for reduction.

Preset sensor range:                          

220 mm Adjustable.

Minimum sensor range:                    

80 mm

Maximum sensor range:                   

300 mm

Security time:                                      

90 seconds

Hot water temperature: 

              

Max 70˚C

     

TECHNICAL DATA

2-3 

     

PACK CONTENTS

     

PRE-INSTALLATION INFO

5-6 

     

Faucet INSTALLATION

                    

 RANGE ADJUSTMENT

          

Adjusting the sensor  settings with a remote control 

8

                        Adjusting the sensor range without a remote control

9                  

BATTERY REPLACEMENT (BATTERY MODELS ONLY)

10 

     

MAINTENANCE

  

          

Filters cleaning instructions

 

          Care and cleaning of chrome and special finishes

11 

    

 SPARE PARTS 

12 

    

 TROUBLE SHOOTING

13                 

 WARRANTY

Содержание Extreme 1000 Plus B 237150

Страница 1: ...1 INSTALLATION AND MAINTENANCE GUIDE E L E C T R O N I C L A V A T O R Y F A U C E T EXTREME SERIES...

Страница 2: ...range 300 mm Security time 90 seconds Hot water temperature Max 70 C 1 TECHNICAL DATA 2 3 PACK CONTENTS 4 PRE INSTALLATION INFO 5 6 Faucet INSTALLATION RANGE ADJUSTMENT 7 Adjusting the sensor setting...

Страница 3: ...treme B 237200 Extreme E 237300 Extreme 1000B 237100 Extreme 1000E 237000 Petite Extreme B 237600 Petite Extreme E 237700 Extreme Plus B 237250 Extreme Plus E 237350 Extreme 1000 Plus B 237150 Extreme...

Страница 4: ...x Optional IP67 Battery Box Familiarize yourself with the part names and confirm that the parts are included ONE INLET battery versions 1 2 3 1 1x Faucet and attachments 2 1x Filter 3 1x Transformer O...

Страница 5: ...attachments 2 2x Filters 3 1x Battery box Optional IP67 Battery box 1 2 3 1 1x Faucet and attachments 2 2x Filters 3 1x Transformer Optional Transformer with IP67 box 1 2 3 TWO INLETS battery versions...

Страница 6: ...btain the missing parts Warnings Do not install the system facing a mirror or any other electronic system operated by an infra red sensor To prevent reflection problems it is recommended to keep a min...

Страница 7: ...alnut thediskandthe gasket Do not remove the O ring from the base of the faucet Step 2 Installing the faucet 1 Place the faucet with O ring into the hole in the deck or lavatory Make sure the O ring i...

Страница 8: ...valves angle valves 4 Check for leaks Step 4 Connecting the power source 1 Connect the power source a For battery versions install the battery s box at the wall underneath the sink using the two side...

Страница 9: ...he red light in front of the sensor will occur At this stage you can change the adjustment by pressing the or buttons every push will increase or decrease one level After finishing the adjustment turn...

Страница 10: ...power supply the sensor will not enter into adjusting mode and the previous setting will return 5 When the sensor enters into the adjusting mode and your hand is in front of the sensor a slow flashin...

Страница 11: ...or light will blink at a constant rate The battery must be replaced within two weeks To replace the battery at battery models 1 Carefully open the battery s box 2 Remove the old battery 3 Replace the...

Страница 12: ...ove the filter s and wash it them under running water 4 Reassemble the parts 5 Make sure that there is no water leakage Care and cleaning of chrome and special finishes DO NOT use steel wool or cleans...

Страница 13: ...ntrol Mixing valve for one inlet models IP 67 Battery box with 6 x 1 5V AA batteries IP 67 Transformer box with 300 mA transformer Power splitter 2 ways Power splitter 3 ways Power splitter 4 ways Cat...

Страница 14: ...ssure that the backcheck prevents from dropping even after water supply pressure drops under 8 bars Debris or scale in diaphragm 1 Sensor is dirty or covered 2 Sensor is picking up reflections from th...

Страница 15: ...ise see STERN Warranty The guarantee does not cover faults labour costs or damage caused by incorrect installation and or maintenance wear and tear battery or water composition This includes but is no...

Страница 16: ...14 15 Gan Rave Blvd 81222 Gan Rave Yavne Israel Tel 972 8 9326000 Fax 972 8 9326025 export sternfaucets com www sternfaucets com 03 09 015237100...

Отзывы: