SETTINgS ADjuSTmENT
mANuAl SETTINgS ADjuSTmENT
The sensor range is the range an object can be away from the sensor in order to activate
the faucet. The sensor is factory preset. If necessary, it can be adjusted as follows:
1
Disconnect the power supply, battery or transformer, from the sensor.
2
Make a short circuit between the (+) and the (-) of the sensor.
You can use a screw driver or another conductor material to make this
short circuit. Alternatively, after disconnecting the power supply, activate
the sensor three or four times.Do not make a short circuit on the power
supply or on the sensor when the power supply is connected to the
sensor.
3
Reconnect the power supply to the sensor.
4
To go into the adjusting mode, put your hand in front of the sensor at a
distance of 2”(5cm) to 4”(10cm) within 5 seconds after the reconnection
of the power supply.
NOTE: If you will not put your hand in front of the sensor after connecting the power
supply, the sensor will not enter into adjusting mode and the previous setting will
return.
5
When the sensor goes into the adjusting mode and your hand is in front
of the sensor, a slow flashing of the red light at the front of the sensor will
occur.
6
Keep your hand at the front of the sensor until the slow flashing changes
into quick flashing. At this point, move your hand to the required distance
from the sensor and wait until the red light will stop flashing.
7
When the red light has turned off, the sensor has been adjusted to the
required distance.
8
Check the distance you have set and if it is not satisfactory, repeat steps
1-6.
RESET bUTTON: This function restores all the factory settings except
for the sensor range. If required, press the Reset button and without
releasing it, press the + button once.
SECURITY TIME: The Security time, prevents continuous flushing of water
due to reflections or vandalism. by default, if the sensor is covered for
more than 90 seconds the water flow will shut automatically. To resume
regular operation any obstruction must be removed.
Press the SEC button. Wait until a quick flashing of the red light of the
sensor eye is perceived. Then, press + to increase the security time and –
to reduce it.
24 HOUR HYgIENE FLUSH: This model includes a 24 hours hygiene flush
which is disabled. To activate the hygiene flush, press the clock button.
Wait until a quick flashing of the blue light in the sensor eye is perceived.
Then press + to activate the hygiene flush. To disable it again, press – to
deactivate it.
COMFORT FLUSH: If your model includes a COMFORT FLUSH setting, it can
be activated by pressing the flush button.
When the button is pressed, one blink of the blue light in the sensor eye
is perceived. The pre-programmed flush cycle will take place then.
The Comfort flush cannot be interrupted or deactivated by pressing any
button until it is over.