![Stern Engineering NARA 2032 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/stern-engineering/nara-2032/nara-2032_installation-and-maintenance-manual_1375294018.webp)
16
S E T T I N G S ADJUSTMENT
DELAY IN TIME:
It is recommended to change the delay in time for
flush valves for urinals or toilets only. Due to the delay in setting, the
sensor will only activate the system if the user is detected for the preset
amount of seconds.
If required, the delay in time can be modified as follows: Press the IN
button. Wait until a quick flashing of the red light of the sensor eye is
perceived. Then, press + to increase the delay in time and – to reduce it.
SHORT FLOW TIME:
This function determines the water flushing
time once the user leaves the W.C. after being present in front of the
sensor for less than a minute. If required, the short flow time can be
modified as follows:
Press the one wave button. Wait until a quick flashing of the red light
of the sensor eye is perceived. Then, press + to increase the flow time
and – to reduce it.
FULL FLOW TIME:
This function determines the water flushing time
once the user leaves the W.C. after being present in front of the
sensor for a minute or more.
Press the two waves button. Wait until a quick flashing of the red light
of the sensor eye is perceived. Then, press + to increase the flow time
and – to reduce it.
ENTRANCE TO THE SELF ADJUSTMENT MODE:
Check that no objects
are in front of the sensor. Press the ADJ button. Once a quick flashing
of the red light of the sensor eye is perceived, remove your hand
holding the remote control and move away from the sensor area. The
ideal sensor range for the specific location will be set automatically.
Ones the self adjustment has taken place the solenoid valve will be
opened and closed for 1 second as an indication that the ideal sensor
range was set and the product is ready for use.
Adjusting other settings with the remote control