![Sterling Power BB122430 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/sterling-power/bb122430/bb122430_user-manual_1375162016.webp)
Sterling Power Products
Copyright
Sterling Power Products
H Charge
Float
In / Unit
Out / Rem
Batt.
V
12.2
Temp
Menu
Change
Volts
Select
Audible alarm on/off
hold > 3 sec
On / Off
hold>3 sec
Fault
Absorption
Cond.
menu
scroll
(unidirection)
6
7
5
1
2
3
4
8
9
Volts Select Button (left)
Quick push = back light on.
Short press ~1 second = input
voltage, press again for output
voltage, press again for remote
sense voltage.
Hold for 4 seconds to toggle
between buzzer on/off,
bu2
should appear.
Remote control:
cut hole diameter
54mm
1) Volts select button.
2) Voltage displayed is voltage into product.
3) LCD screen with backlight.
4) Fast charge led indicator.
5) Condition battery stage.
Temp Menu Change (right
button)
Quick press = back light on.
Short hold ~1 second = switch
between unit’s temperature
and temperature sensor. If
nc
appear it means that the
temperature sensor is not
connected.
Hold for 2 seconds to toggle
night mode on / off,
nn
should
appear. 1/2 power for 8 hours.
Hold button for 4 seconds
to enter the Setup Menu -
“rt” shall appear.
3
3
Both Left and Right buttons
Hold both buttons for 2 seconds
to force to float
FtF
, toggle on / off.
Press and hold both buttons for 4
seconds to enter standby mode,
Stb
should appear. Repeat to turn
unit on.
Press and hold both buttons for 6
seconds to turn unit off.
oFF
shall
appear. Repeat to turn unit on.
Volts
Select
Volts
Select
Temp
Menu
Change
Then the actual value. Press “change” button to increase value.
Hold “change” button to accelerate. When max. value reached
it will start with lowest value. Press “select” again to confirm
setting. Press “change” button to increase value. Hold “change”
button to accelerate. When max. value reached it will start with
lowest value. Press “select” again to confirm setting.
“b9b”
change voltage from green to blue backlight 12.4 -
*
16.0V (default 13.4V). Press “select” .First the lowest and the
hightest value will be displayed. Then the actual value. Press
“change” button to increase value. Hold “change” button to
accelerate. When max. value reached it will start with lowest
value. Press “select” again to confirm setting.
“Led”
change LED on time 1 - 600 seconds, 0 = always on,
(default = 60). Press “select” .First the lowest and the hightest
value will be displayed. Then the actual value. Press “change”
button to increase value. Hold “change” button to accelerate.
When max. value reached it will start with lowest value. Press
“select” again to confirm setting.
“uId”
display Unit ID. Press “select”. Value will be displayed for
5 sec.
“uSW”
display unit software version. Press “select”. Value will
be displayed for 5 sec.
“rSW”
display remote software version. Press “select”. Value
will be displayed for 5 sec.
“Loc”
Unit lock code = 1 to 999 (default = 00 = unlocked).
WARNING
This mode shall lock menu setting options of the
unit by virtue of a pass code, be careful. Press “select” to enter
“Loc” setting. Press “change” button to increase value, hold to
accelerate. Stop when on the number you require and press
“select” button to confirm. The software shall store this number,
then the display shall read:
loc
-> on -> #. # = number you have
stored. To remove
loc
, return to
loc
and re-enter the number,
Press “select” button and the display should read:
loc
-> off
(green back light).
Please make a note of this loc code
here:_______
.
“rSt”
Resets remote to default values*. Press “select”. “NO”
will be displayed. Press “change” to toggle between “YES” and
“NO”. Confirm by pressing “select”. rSt will display if resetting.
“rSu”
Resets the battery charger to default settings. Press
“
” “NO”
“
”
select .
will be displayed. Press change to toggle
between YES and
.
“
”
“NO” Confirm by pressing “select”. rSt will
display if resetting.
“rt”
displays remaining absorption or conditioning time
Press “select” button to see value.
“btY”
displays battery profile type (0-9). This number
denotes which charging profile the charger is set to. Press
“select” to see value. (Ref: table labelled ‘Battery Chemistry
Selection’ on).
“coU”
displays input cut off voltage (the voltage at which the
unit stops charging) (13.4V). Press “select” to see value.
“IoU”
display input / output base voltage (12/24V). Press
“select”. First input voltage will be displayed with “in” LED on
for 3 sec. then output voltage with “out” LED on for 3 sec.
change from celcius to fahrenheit or back (default =
“C/F”
*
celcius). Press “select” button to enter setting. Then press
right button to change between Fahrenheit (FAH) and
Celsius (CEL). Confirm setting by pressing “select” button.
“CL”
set current limit to 1/2 or 1/1 (full). Press “select” button
to see actual setting. Press “change” (right) button to
change setting. Press “select” to confirm setting.
“buC”
turn Buzzer on / off (default = on). Press “select” to
*
see actual setting. Press “change” button to change
between settings. Press „select“ again to confirm setting
Autoscroll on / off (default = off). Press “select” to see
“Asc”
actual setting. Press “change” button to change between
settings. Press “select” again to confirm setting.
“Von”
Voltage / temp display during standby and sleep.
Toggle between on and off, press “select” (left) button to
select.
“con”
change contrast value from 0 to 7 (default = 3).
*
Press “select”. First the lowest and the hightest value will be
displayed. Then the actual value. Press “change” button to
change settings. Press “select” again to confirm setting.
change backlight colour . off <- auto -> green -> red -
“bLc”
*
> blue (default = auto). Press “select” to see actual setting.
Press “change” button to change between settings. Press
“select” again to confirm setting
.
“bLt”
change backlight time . 1 - 600 seconds, 0 = always
*
on, (default = 60). Press “select”. First the lowest and the
hightest value will be displayed. Then the actual value.
“br9”
change remote display colour red to green voltage
threshold.*
8.0V-13.3V (default 12.4V). When below 12.4V
display is red and when 12.4V or above the remote goes
green. When Press “select”. First the lowest and the highest
value will be displayed.
6) Charge complete on float.
7) Voltage displayed is volts out of product.
8) Scroll menu button.
9) Screen display showing a unit fault.
Temp
Menu
Change
Temp
Menu
Change
Setup - Menu:
Toggling is unidirectional
to escape menu hold both buttons down until ‘END’
appears. Or, just leave the remote for 10 seconds.
Remote Error Codes
E00
= high input voltage
E01
= high output voltage
E02
= high unit temp
E03
= high batt. temp
E04
= no output voltage
16
Remote Control