CUSTOM BATTERY TYPE SETTING
(for expert use
only - not required for general operation)
Before proceeding with this, please read and
understand all instructions as it is quite complex and
could take more than one attempt. There are timed
intervals of 30 seconds per setting so it is very
important to know exactly what you require before
starting. If any errors are made simply wait a few
minutes and you can start the cycle again. The
settings offered for adjustment in sequence:
Important information:
If during these operations
you get yourself in a mess and find yourself pushing
buttons aimlessly, then please resort to the factory
reset. To delete all and return the product to its default
factory settings.
A)
Boost / absorption voltage (high voltage charge).
B)
Conditioning voltage (medium charge rate
normally between boost and float voltage).
C)
Float voltage (no longer charging, this will provide
voltage at a reduced level to maintain the batteries
and provide power for any loads applied).
D)
Absorption time factor adjust. The length of time
spent in absorption can be adjusted by a factor 0-18.
This may be beneficial for different battery
chemistries. Gel, for example, tends to absorb current
at a low rate, thus, increasing the length of time spent
in absorption may be beneficial (set nearer 18). AGM,
the reverse (set nearer 0). If in any doubt, ask your
battery retailer or simply use one of our preset values.
To calculate the absorption time from the time factor
simply multiply the factor number (0-18) by the length
of time it takes for the charging voltage to hit the
absorption voltage (typically 14.4V). If it takes 40
minutes to reach absorption and you set your ATF to 4
then 4x40mins = 160 minutes. The maximum time the
unit can stay in absorption is 24 hours 1440 minutes.
E)
Minimum and maximum absorption times.
Here you can set the maximum and minimum time the
unit stays in absorption. For example, you may have
AGM that may need a maximum of one hour, or GEL
which could require a minimum of 720 minutes (12
hours).
We recommend that you write down your required
voltages and times in the space below. This is so you
know what to programme during setup.
Desired custom values - make a note.
Boost / bulk / absorption (V) ________
Conditioning (V)
________
Float (V) ________
Absorption Time Factor (0-18) ________
Absorption Minimum (0-960 minutes) ________
Absorption Maximum (0-960 minutes) ________
Operation
Press and hold SETUP button for 10 flashes, let go.
All of the first column of LEDs shall flash
Press the setup/select button to move LED down to
custom. Hold both buttons for 2 seconds to confirm.
S
TERLI G
P
OWER
Opportunity to adjust Fast Charge / Bulk /
Absorption voltage
.
Red Custom LED
will flash for 3 seconds to confirm.
Red Custom LED
will come on constant,
Green Fast
Charge LED
will flash (section 1 on graph). Adjust
Fast Charge voltage by using the Select and Setup
buttons to go up and down the right LED column to
select the correct Fast Charge voltage. Once content,
wait 30 seconds, or press both buttons to confirm. The
unit shall then proceed to Conditioning charge voltage
(next below).
Opportunity to adjust Conditioning charge
voltage
Red Custom LED
will come on constant and
Green
Conditioning LED
will flash (section 3 on graph).
Likewise, adjust the conditioning voltage by using the
Select and Setup buttons to go up and down the right
LED column to select the correct Conditioning
voltage. Once content, wait 30 seconds, or press both
buttons to confirm. The unit shall then proceed to float
voltage set (next below).
Opportunity to adjust float charge voltage
Red Custom LED
will come on constant and
Blue
Float LED
will flash (section 3 on graph). Likewise,
adjust the float voltage by using the Select and Setup
buttons to go up and down the right LED column to
select the correct Float voltage. Once content, wait 30
seconds, or press both buttons to confirm. The unit
shall then proceed to float voltage set (next below).
Opportunity to adjust absorption time factor
Red High Temp LED
will come on constant.
Green
Fast Charge LED
will flash and
will
Blue Float LED
flash (section 1 and 4 on graph). This time, adjust the
time by using the Select and Setup buttons to go up
and down the right LED column (
refer to the blue scale
scale 0-18
) to select the correct time. Once content,
wait 30 seconds, or press both buttons to confirm. The
unit shall then proceed to minimum absorption time
factor (next below).
Why use Absorption Time Factor (ATF)?
ATF is simply a number (0-18) that can be used to
multiply by the length of time the charger takes to
reach the absorption voltage from start. For example,
if the absorption voltage is reached in 10 minutes with
the ATF at 4, then 10mins x (ATF 4) = 40 mins of
absorption.
Opportunity to adjust minimum absorption time
factor
Red High Temp LED will come on constant.
Yellow
Absorption LED
will flash and
will flash
blue Float
(section 2 and 4 on graph). This time, adjust the time
by using the Select and Setup buttons to go up and
down the right LED column (
refer to the brown scale 0-
960
) to select the correct time. Once content, wait 30
seconds, or press both buttons to confirm. The unit
shall then proceed to maximum absorption time factor
(next below).
Custom Settings
15
# flashes
only button
Setup
0-1
Silence Buzzer /
Status display / Change to voltage display
5
Software version
10
Select battery type
15
Power supply mode / live output voltage
20
Pure ignition feed mode
25
Change operational on/off voltage
30
Set auto regen. braking timer
35
Temperature voltage compensation
40
Buzzer off (long term)
45
Maintenance Mode
+2
0
-2
-4
-6
-8
-10
-12
-30
C
o
After custom charging profiles have been set, the last
option in the custom procedure is to set temperate trip.
The default, as it assumes lead acid, is -30 Deg C, so
the RED LED at the bottom shall illuminate. For
lithium, bring this LED up to your desired trip
temperature. E.g 0, -2, -4 Deg C etc.
Opportunity to adjust minimum absorption time
factor
Red High Temp LED
will come on constant.
Yellow
Absorption LED
will flash and
will flash
blue Float
(section 2 and 4 on graph). This time, adjust the time
by using the Select and Setup buttons to go up and
down the right LED column (
refer to the brown scale 0-
960
) to select the correct time. Once content, wait 30
seconds, or press both buttons to confirm. The unit
shall then proceed to maximum absorption time factor
(next below).
14