Sterling Power Products
Copyright
Force Options
13
Silence Buzzer
If the buzzer is sounding and you wish to silence it, simply press SETUP button with a quick but firm press. This should
silence the buzzer. It is a short term feature. If you wish to turn the buzzer off forever, please press the SETUP button
down for 40 flashes.
to view the status of the charger - do a quick press.
to view the BB as a voltmeter - do a quick press.
Display temperature
If you wish to view the temperature at the battery temperature sensor (if installed) - you can view it here. The
temperatures that can view are between -30DegC and +2DegC on the front panel. If you wish to view a full range of
temperature then you shall need the remote control BBURC.
Force unit to float
We recommend that you understand what float means before committing to float mode. It is basically a lower
maintenance voltage - fairly harmless. Once you have forced the unit into float mode it shall remain there, forever - until
you either do a factory reset or repeat this procedure.
Force unit to 1/2 power mode
This mode shall put the charger into half power mode. As the name suggests, if you have a 60A charger it shall put the
maximum current to 30A. A 30A BB charger shall reduce to 15A (approximately) etc... The BB shall remain at half power
forever, until either a factory reset is done or this method is repeated. You may need this mode if you want to reduce the
current for the sake of keeping within the maximum charge rate of your batteries or due to pre-existing cabling being
insufficient for the full power of the charger.
Force unit to night mode
This mode shall put the charger into half power mode (as above) but only for 8 hours at a time. The BB shall be on half
power mode for these 8 hours only. It shall then resume as normal full power after these 8 hours. You have to repeat this
procedure every time you need it.
Turn the charger to standby
If you wish to put your BB into standby then apply this mode. Standby is a one off setting. It shall stop the boost of the BB but
shall remain on - pending a button press to get out of standby. The BB shall come out of standby during the next charge
cycle, so is not a permanent setting. To indicate that standby is on LEDs 12 and 15 shall flash. Press any button to take out of
standby.
Turn charger off
If you wish to turn your BB off then apply this mode. Off means the BB shall stop charging awaiting you to press either button.
To turn off is a one off indefinite setting. It shall stop the boost of the BB - pending a button press to get out of standby. The BB
shall turn on again only when a button is pressed. If the charger is disconnected and reconnected the BB shall remain off,
also, during power cycles it shall remain off. To display the charger being off the top row of LEDs 12, 13,14,15 shall flash.
OEM lock
If you are an installer and wish to make settings to the BB and then lock the charger in these settings, to prevent tampering
by the end user, then apply OEM lock. Once this mode has been applied NO options can be adjusted. Factory reset is the
only method to remove this feature and restores the BB to defaults. The BB demonstrates OEM lock by flashing 4 Red
corner LEDs.
quick press
# flashes
Action
0-1
Silence Buzzer
5
Display temp
10
Force to Float
15
1/2 Power Mode
20
Night mode
25
Standby
30
Turn unit off
35
40
OEM Lock
5 flashes
10 flashes
15 flashes
20 flashes
25 flashes
30 flashes
40 flashes
Maintaince mode, this mode lock on the unit so it does not switch
off, and keeps the input and output volt meters in operation which
you work on the system for fault finding. if ther is a fault and the
output voltage leds only are on then its no longer a volt meter
display it is simply displaying a fault condition which needs to be
resolved, the unit is only displaying voltage if both rows off leds are
active
# flashes
Select
only button
0-1
Silence Buzzer
5
Display temperature
10
Force to float
15
Night Mode
20
1/2 Power Mode
25
Standby
30
Turn unit off
35
Batt Maintainer on / off
40
OEM Lock
45
Solar Charger on*/off
50
BB Charger on*/off
55
BB + Solar mode on/off*
BBS solar only
Solar charger on* / off
the solar charge feature of the
BBS1230 can be turned off, if not
required. Default is on. Press the
SELECT button for 45 flashes
and let go, to turn off.
BB charger on* / off
If you wish for the BBS1230 to be pure a solar charger
and for the BB aspect to be switched off - use this mode.
Press the SELECT button for 50 flashes and let go to
turn the BB charging off. Solar charging ONLY! May be
ideal for a bright sunny day and you wish to save a very
small amount of fuel.
BB + Solar mode on* / off
This mode turns the entire BBS off.
Both the solar charger and BB charger
turns on / off with this feature. Default is
on. To turn off press SELECT button for
55 flashes.
45 flashes
50 flashes
55 flashes
BBS1230 only
BBS1230 only