background image

BR-600

0816A

V1.1

CAUTION

Parts

Controls

Specifications

• This device cannot be used by people with different abilities, unless they have 

preparation and supervision.
• This product is NOT a toy; keep it away from children.
• Never leave the clamps without connecting with the charger connected to the mains.
• Do not use this charger in damp or wet environments.
• Before connecting the charger to the battery voltage check it.

1. Harness with alligator connectors

2. Harness with eyelet connectors 

3. Charger

Mode button

Power Error

Charge level

Operation mode

Recovery

Reverse polarity

1. Select type of tips that fit 
your needs and connect 
corresponding harness to 
the charger.

3. Press the MODE button to select the 

connected battery voltage (6 or 12 V). It 

lights up the LED corresponding to the 

selected operating mode

8. The charging will begin and the led indicators will light up one by 

one according to the charge level. If battery has very low voltage, the 

charger will enter in recovery mode and the corresponding LED will 

turn on (a moment may pass). When charging is complete and 

100%LED will turn on, the charger will turn to floating charge status(If 

floating charge status keep more than 72hours, the battery charger 

will be closed for safe protected). When the battery is charged, you can 

disconnect the charger.

7. Plug the power cord of 

the charger into a home 

outlet. The power LED 

will turn on.

9. To disconnect the charger, remove the power cord from 

the outlet, first remove the red lead, and finally, disconnect 

the black tip.

Input: 110 a 120 V ~ 50 / 60 Hz  22 W máx.
Output: 12, 6 / 6,3 V  - - - 1  A
Consumption: 13 W/h
Stand-by consumption:  1,8 W/h

5. Connect the black tip of 
the charger to the negative 
terminal of the battery.

6. Connect the red tip of the 
charger to the positive terminal 
of the battery.

Please note that if you connect the battery before connect the 
power outlet, the battery charger mode can not be selected, it 
will use the last select mode(6V or 12V), that will be a frequently 
operation error.

4. To disconnect the charger, 
remove the power cord from the 
outlet, first remove the red lead, 
and finally, disconnect the black 
tip.

Before using your new product, read the following instructions

Ultrasmart  acid  battery charger 

Functioning

MODE

25%

6 V

12 V

RECOND

REVERSE

50%

75%

100%

MODE

25%

6 V

12 V

RECOND

REVERSE

50%

75%

100%

MODE

25%

6 V

12 V

RECOND

REVERSE

50%

75%

100%

!

-

+

-

+

2. Plug the power cord of the 
charger into a home outlet. The 
power LED will turn on.

MODE

25%

6 V

12 V

RECOND

REVERSE

50%

75%

100%

MODE

25%

6 V

12 V

RECOND

REVERSE

50%

75%

100%

WARRANTY

This Steren product is warranted under normal usage against defects in workmanship and materials to the original purchaser for one year from the date of 

purchase.

CONDITIONS

1. This warranty card with all the required information, invoice, product box or package, and product, must be presented when warranty service is required.

2. If the product is in the warranty time, the company will repair it free of charge.

3. The repairing time will not exceed 30 natural days, from the day the claim was received.

4. Steren sell parts, components, consumables and accessories to customer, as well as warranty service, at any of the addresses mentioned later.

THIS WARRANTY IS VOID IN THE NEXT CASES:

If the product has been damaged by an accident, acts of God, mishandling, leaky batteries,

failure to follow enclosed instructions, improper repair by unauthorized personnel, improper

safe keeping, among others.

a) The consumer can also claim the warranty service in the purchase establishment.

b) If you lose the warranty card, we can reissue it, if you show the invoice or purchase ticket.

RETAILER INFORMATION

Name of the retailer _______________________________________________

Address ______________________________________________________

Product _______________________________________________________

Brand ________________________________________________________

01 800 500 9000

In case your product fails or 

have questions, please 

contact your nearest dealer. If 

you are in Mexico, please  

call to our Call Center. 

Product: Ultrasmart acid battery charger

Part number: BR-600

Brand:  Steren

Other operating conditions:

INDICATOR

CONDITION

PROCESS

RECOND

ERROR

Very low voltage level

(Mode charger

Recovery)

Battery damaged or irrecoverable

Leave the charger connected to the battery for a period of 10 to 15 minutes. It will go to 
normally charge(it will light the LED charge level 25%).

REVERSE

Reverse polarity

Correctly connect the tips: The black tip on the negative side and red on the positive.

1

2

3

ERROR led constant light, please try below solution:
1. Please check if the 6V/12V Mode select right, if Mode select wrong, please 
select right mode as above "Functioning" step.
2. If Mode is selected right, the battery maybe damaged by over discharge. Please 
try below steps to recover the battery:
1)Disconnect the tip of the positive terminal.
2) Wait about 10 seconds to reconnect the tip.
After connecting, it should charge normally (it will light the LED charge level 25%) 
or in recond mode((it will light the LED RECOND), if it does not work, please try 
several times, and if it still does not work, it means the battery is damaged and 
irrecoverable. Please replace the battery.

ERROR led flashing light, it means that the battery can not be recovery or the 
battery do not have reserve capacity of electricity. Please replace the battery.

C

M

Y

CM

MY

CY

CMY

K

BR-600-V1.1-instr.pdf   2   12/08/16   12:44 p.m.

Отзывы: