3 Potential Hazards

3.1 Auxiliary Power

The electricity produced by an engine driven Generator is very similar to mains
electricity and should be treated accordingly.

Do not remove covers and attempt to work on the Generator while the engine is
running.

Check the rating and electrical safety of the load before connecting the
Generator.

Equipment should never be connected that in total exceeds the specified rating
of the Generator.

Installation of the generator as a standby or secondary power source should
only be undertaken by a fully qualified electrician using the appropriate means
of isolation from the mains supply. Installation must comply with all applicable
laws and electrical codes.

3.2 Operating Environment 

The Generator should always be operated on level ground.

3.3 Temperature Range

A temperature range between -10

o

C and +40

o

C are the normal limits of

operation. 
Operating outside the range will require additional modifications.

3.4 Reference Relative Humidity

The standard reference condition for relative humidity is 30%. Above this value
the rated power must be reduced.

3.5 Reference Barometric Pressure

The standard reference condition for total barometric pressure is 1 bar.

This corresponds to an altitude of approximately 100m.  Above 100m the rated
power must be reduced.

3.6 Flammable Environment

Stephill Generators must not be used in a flammable environment.

3.7 Saline Environment

Operation of the machine in a saline environment will require additional
corrosion protection.

4 Safety Considerations

4.1 General

All Stephill Generators comply with all the current EEC directives including, the
the noise emission in the environment by equipment for use outdoors regulation
2001 (SI 2001/1701).

Содержание SE6000D

Страница 1: ...HIS MANUAL AND ENGINE MANUFACTURER S OWNER S MANUAL AND WARNINGS THIS STEPHILL GENERATOR HAS BEEN DESIGNED TO PROVIDE SAFE AND EFFICIENT SERVICE IF OPERATED AND MAINTAINED CORRECTLY MANY ACCIDENTS OCC...

Страница 2: ...4 5 Earth connection 3 4 6 Fumes 3 4 7 Noise 3 4 8 Battery acid 3 4 9 Fire 4 4 10 Hot parts 4 5 OPERATING INSTRUCTIONS 4 5 1 Pre Start checks 4 5 2 Warning 3 5 3 Starting instructions 4 5 4 Fuel syst...

Страница 3: ...e damaged should be replaced The following are shown on the generator 2 2 Safety Hazards Do not climb on the generator as dents may cause overheating of the acoustic lining It is important to keep the...

Страница 4: ...rated on level ground 3 3 Temperature Range A temperature range between 10o C and 40o C are the normal limits of operation Operating outside the range will require additional modifications 3 4 Referen...

Страница 5: ...ipment should not be attached directly to the Engine Alternator except for lifting of Engine Alternator only 4 5 Earth Connection All Stephill products are fitted with an earth stud on the control pan...

Страница 6: ...it from starting if the fuel level is low The engine is equipped with an oil and temperature switch and will shutdown for low oil pressure and high engine temperature 5 2 Warning Do not operate the ch...

Страница 7: ...pipe Now the fuel system has been bled and the generator should start 7 If Engine still will not start repeat steps 1 5 but turn key to start position and diesel should squirt out of delivery valve h...

Страница 8: ...mage to the piping and cables which could result in a fire Do not service or work on generator whilst the engine is running and ensure the ignition key is removed 6 1 Engine Service Service the engine...

Страница 9: ...rning light 1 045 0001 Key switch 1 045 0017 Bulb 4 056 0001 Relay 5pin 12V DC 3 10 WARRANTY This generator supplied by STEPHILL GENERATORS LTD carries a warranty of 12 months from date of despatch or...

Страница 10: ...8...

Страница 11: ...9...

Страница 12: ...10...

Страница 13: ...11...

Страница 14: ...Stephill Generators Ltd Wallis Close Park Farm South Wellingborough Northants NN8 6AG Tel 44 0 1933 677911 Fax 44 0 1933 677916 E mail info stephill generators co uk www stephill generators co uk...

Отзывы: