Stephill SE6000D Скачать руководство пользователя страница 2

Page

1

SPECIFICATION

1

2

GENERAL SAFETY

1

2.1

Warning signs

1

2.2

Safety hazards

1

3

POTENTIAL HAZARDS

2

3.1

Auxiliary power

2

3.2

Operating environment

2

3.3

Temperature range

2

3.4

Reference relative humidity

2

3.5

Reference barometric pressure

2

3.6

Flammable environment

2

3.7

Saline environment

2

4

SAFETY CONSIDERATIONS

2

4.1

General

2

4.2

Fuel

3

4.3

Lubricating oil

3

4.4

Safe lifting

3

4.5

Earth connection

3

4.6

Fumes

3

4.7

Noise

3

4.8

Battery acid

3

4.9

Fire

4

4.10

Hot parts

4

5

OPERATING INSTRUCTIONS

4

5.1

Pre-Start checks

4

5.2

Warning

3

5.3

Starting instructions

4

5.4

Fuel system bleeding procedure

4

5.5

Control panel

5

5.6

Long term storage

5

6.0

SERVICE AND MAINTENANCE

6

6.1

Engine service

6

6.2

Alternator service

6

7.0

NAC Alternator spares

6

8.0

Yanmar consumable spares

6

9.0

SE6000D Spares

7

10

WARRANTY

7

APPENDICES

SE6000D Dual voltage wiring diagram

8

SE6000D L100 Engine wiring diagram

9

SE6000D Base exploded view

10

SE6000D Roof exploded view

11

Contents

Содержание SE6000D

Страница 1: ...HIS MANUAL AND ENGINE MANUFACTURER S OWNER S MANUAL AND WARNINGS THIS STEPHILL GENERATOR HAS BEEN DESIGNED TO PROVIDE SAFE AND EFFICIENT SERVICE IF OPERATED AND MAINTAINED CORRECTLY MANY ACCIDENTS OCC...

Страница 2: ...4 5 Earth connection 3 4 6 Fumes 3 4 7 Noise 3 4 8 Battery acid 3 4 9 Fire 4 4 10 Hot parts 4 5 OPERATING INSTRUCTIONS 4 5 1 Pre Start checks 4 5 2 Warning 3 5 3 Starting instructions 4 5 4 Fuel syst...

Страница 3: ...e damaged should be replaced The following are shown on the generator 2 2 Safety Hazards Do not climb on the generator as dents may cause overheating of the acoustic lining It is important to keep the...

Страница 4: ...rated on level ground 3 3 Temperature Range A temperature range between 10o C and 40o C are the normal limits of operation Operating outside the range will require additional modifications 3 4 Referen...

Страница 5: ...ipment should not be attached directly to the Engine Alternator except for lifting of Engine Alternator only 4 5 Earth Connection All Stephill products are fitted with an earth stud on the control pan...

Страница 6: ...it from starting if the fuel level is low The engine is equipped with an oil and temperature switch and will shutdown for low oil pressure and high engine temperature 5 2 Warning Do not operate the ch...

Страница 7: ...pipe Now the fuel system has been bled and the generator should start 7 If Engine still will not start repeat steps 1 5 but turn key to start position and diesel should squirt out of delivery valve h...

Страница 8: ...mage to the piping and cables which could result in a fire Do not service or work on generator whilst the engine is running and ensure the ignition key is removed 6 1 Engine Service Service the engine...

Страница 9: ...rning light 1 045 0001 Key switch 1 045 0017 Bulb 4 056 0001 Relay 5pin 12V DC 3 10 WARRANTY This generator supplied by STEPHILL GENERATORS LTD carries a warranty of 12 months from date of despatch or...

Страница 10: ...8...

Страница 11: ...9...

Страница 12: ...10...

Страница 13: ...11...

Страница 14: ...Stephill Generators Ltd Wallis Close Park Farm South Wellingborough Northants NN8 6AG Tel 44 0 1933 677911 Fax 44 0 1933 677916 E mail info stephill generators co uk www stephill generators co uk...

Отзывы: