STEP
i
AStar
Frequency Inverter For Elevator Door Machine manual Instructions
67
F30
√
√
√
√
F31
√
√
√
√
F32
√
√
√
√
F33
√
√
√
√
F34
×
√
√
√
F35
√
√
√
√
instructions
:
‘
√
’---- available in current mode
‘
×
’---- void in current mode
appendix 2
:
compact debugging curve of inverter (This figure can be cut and pasted on the installation
location of door, easy to debug)
F11
%
100
F11
~
F16 unit:rpm; F17
~
F20 unit:r/10ms; F22
~
F25 unit:%
F20
curve of door openning and closing:when F03=0/1/2, adjust
F11
~
F25; whenF03=3, adjust F11
~
F20
%
F22[<20 ]
For type A2, after setting F38=3, parameters canbe modified
and saved by connect 17(INPUT8) and 18(COM)
Openning Process
%
100
F12
F13
F14
F03=0: adjustment of F42 can reduce noise when door openning.
adjustment of F51 can adjust output torque
closing Process
F18
%
F24[>50 ]
%
0
F19
F16
F15
adjustment of F33 can adjust the speed of holding door openning
and closing. adjustment of F30 and F31 can adjust the touque of
holding door openning and closing.
%
F25[<50 ]
%
F23[<20 ]
Percentage of
Door Position
%
0
Percentage of
Door Position
F17
F03=1/2/3: adjustment of F34 can adjust output torque