Shanghai STEP Electric Co., Ltd.
44
6.2.2.3 Display of panel operator
Panel operator will debug fault information and display it in real time,
In interface of
【
Para Revises
】
,
value being modifying is blink
Information is shown as following
:
1
、
display fault code
Display form
:
E xxxx
E
:
fault
xxxx
:
fault number
(
1~20
)
parameter information of fault
:
xxxx
(
fault code
)
2
、
display monitor state
display form
:
Uxxxx
xxxx: state code
(
0~15
)
parameter display form
:
xxxxx
value of U11
,
U12 is binary
,
display form
:
xxxxxxxx
long upright means 1
,
short upright means 0
3
、
display code parameter L
display form
:
L0000
4
、
browse and steup of parameter F
display form
:
Fxxxx
xxxx:code number
(
0~97
)
parameter display form
:
xxxxx
value of F36
,
F37 is binary
,
display form
:
xxxxxxxx
long upright means 1
,
short upright means 0
5
、
display code parameter P
display form
:
P0000
6
、
state of opening and closing
display form
:
CL xxx:
CL
:
closing
parameter display form
:
xxx: percentage of closing
(
0~99
)
display form
:
OP xxx:
OP
:
openning
parameter display form
:
xxx: percentage of openning
(
0~99
)
ps
:
L
:
Login
P
:
Password
E
:
fault mark
U
: