3.5.2.2 Wiring specifications of encoder
There are 2 kinds of encoder input signals for door inverter——encoder of Push/pull
or OCT type. Please choose the encoder below 1024 pulse and using 24V power
supply.
VCC
GND
PA
PB
Push/Pull output encoder
iAStar inverter for door machine
using shielded wires
shielded wire connected to
19
20
21
22 +24V
+24VGND
PA
PB
OCT encoder
GND with close terminal
Fig 3-13 diagram of Push/pull or OCT output encoder wiring for Type A2/A3
On the wiring of push/pull or OCT output encoder, the power of encoder should be
jointed at +24V terminal, the encoder ground at +24V GND terminal, PA and PB of
encoder at PA and PB of inverter, and the close terminal of shielded wire at GND
terminal of inverter.
。
3.5.2.3 Specification of terminals swich Wiring
14
15
16
18
Terminal swich
iAStar inverter for door machine
Using shielded wires
Shielded wire connected to GND with close terminal
Door openning to position signal
Decelerating point of door openning
Door closing to position signal
Decelerating point of door closing
COM