Shanghai STEP Electric corporation
II
Preface
The
-S3 Series of elevator-used Inverters is a new type inverter which is
researched and developed based on the carry characteristic of elevator. The 32
bit electromotor-used Digital Signal Processing (DSP), Complex Programmable
Logic Device (CPLD), Intelligent Power Module (IPM) and the digiral vector
controlled frequency-variable speed-adjustable technology are used in the
Inverter. It also combines the model characteristic of potential energy. All of them
ensure stable, comfortable and efficient running of elevator.
Outline
This instruction manual describes installation, operation, function constants
setting, maintenance and trouble-shooting of the
-S3 Inverter. The
manual can be the reference for designing the elevator control system by using
the
-S3 Inverter. It also can be the reference of installation,
commissioning and maintenance of elevator.
Please read the manual carefully before installing and operating the inverter.
Reader
User
Designer of elevator control system
Maintenance engineer
Technical supporter
Innovations
a) The innovative starting compensation technique without load sensors
provides an excellently comfortable starting of elevator.
b) The new PWM dead-zone compensation technique can effectively reduce
motor noise and wearing.
c) There is no need to run autotuning for asynchronous motor.
d) There is no need to lift the car during self-tuning of the phase angle of
elevator with synchronous motor.
Содержание iAStar-S3
Страница 1: ......
Страница 2: ......
Страница 18: ......
Страница 26: ......
Страница 32: ......
Страница 86: ......
Страница 124: ......
Страница 127: ...Instruction Manual of S3 Inverter for Elevator Figure 7 1 Internal control of the Inverter Application of Elevator 7 3 ...
Страница 163: ...Instruction Manual of S3 Inverter for Elevator pection Fault Ins 8 5 ...
Страница 164: ...Shanghai STEP Electric corporation The motor runs without speed variation pection Fault Ins 8 6 ...
Страница 168: ......
Страница 196: ......
Страница 198: ......
Страница 200: ......