Instruction Manual of
-S3 Inverter for Elevator
Continued
Function
Code
Name
Content
Range
Unit
Default
Remarks
速度参考
5
D16
Speed Ref. 5
Reference speed 5 under
multi-step control, in m/s.
1.000
速度参考
6
D17
Reference speed 6 under
multi-step control, in m/s.
1.500
6-
17
Function Parameter List
Speed Ref. 6
速度参考
7
0.000
~
3.000
m/s
Reference speed 7 under
multi-step control, in m/s.
D18
Speed Ref. 7
1.750
Note 1:
D parameters are used to set up the S curve during elevator operation. Except for
D03 (dwell speed) and D08 (dwell time), other D parameters are valid only when the
speed is given through digital multi-step control. When the speed is given through analog
inputs, other D parameters except D03 and D08 are invalid.
Note 2:
the multi-step operation curve is shown in Figure 6.8.
Figure 6.8 Multi-step operation curve
Note 3:
D01 - D08 are used to set up the S curve (speed curve) during elevator operation
under digital multi-step control. They define acceleration (D01), deceleration (D02),
acceleration jerk (D04 and D05) and deceleration jerk (D06 and D07), and thus directly
influence the operation efficiency and comfort of the elevator. Dwell speed (D03) and
dwell time (D08) mean that: when the speed is given through digital multi-step control, at
the starting of the elevator, a dwell speed will be given first, and a normal speed will be
given after the dwell time; when the speed is given through analog inputs, at the starting of
the elevator, a dwell speed will be given first, and an analog speed will be given when the
analog speed exceeds the dwell speed or after the dwell time. Under special
circumstances, adjustments to these two parameters may increase elevator comfort. It
shall be noted that, under most circumstances, there is no need for a dwell speed, the
dwell time (D08) shall be set to 0, and the elevator will start with a normal given speed.
The parameters along the elevator operation curve are shown in Figure 6.9.
Figure 6.9 S Curve during elevator operation
Содержание iAStar-S3
Страница 1: ......
Страница 2: ......
Страница 18: ......
Страница 26: ......
Страница 32: ......
Страница 86: ......
Страница 124: ......
Страница 127: ...Instruction Manual of S3 Inverter for Elevator Figure 7 1 Internal control of the Inverter Application of Elevator 7 3 ...
Страница 163: ...Instruction Manual of S3 Inverter for Elevator pection Fault Ins 8 5 ...
Страница 164: ...Shanghai STEP Electric corporation The motor runs without speed variation pection Fault Ins 8 6 ...
Страница 168: ......
Страница 196: ......
Страница 198: ......
Страница 200: ......