INSSTE402NP0711
2
WARNING
Before installing and operating this product,
the owner and/or installer must read,
understand and follow these instructions and
keep them handy for future reference. If these
instructions are not followed, the warranty
will be considered null and void and the
manufacturer deems no further responsibility
for this product. Moreover, the following
instructions must be adhered to in order to
avoid personal injuries or property damages,
serious injuries and potentially fatal electric
shocks. All electric connections must be made
by a
qualified electrician
, according to the
electric and building codes effective in
your region
. Do NOT connect this product
to a supply source other than 120 VAC, 208
VAC or 240 VAC, and do not exceed the load
limits specified. Protect the heating system
with the appropriate circuit breaker or fuse.
You must regularly clean dirt accumulations
on the thermostat. Do NOT use fluid to clean
thermostat air vents
1. Description
The electronic thermostat STE402NP can be used to
control electric heating units such as electric base-
boards, convectors, or aeroconvectors. It keeps
the temperature of a room at the requested set
point with a high degree of accuracy. This product
is designed for installations with electrical current -
with a resistive load - ranging from 1.2 A to 16.7 A
(150 to 2000 W at 120 VAC, 260 to 3475 at 208 VAC
and 300 to 4000 W at 240 VAC).
This thermostat is not compatible with the
following installations
• electrical current higher than 16.7 A with a resis
-
tive load (4000 W @ 240 VAC, 3475 W @ 208 VAC
and 2000 W @ 120 VAC);
• electrical current lower than 1.2 A with a resistive
load (300 W @ 240 VAC, 260 W @ 208 VAC and
150 W @ 120 VAC);
• inductive load (presence of a contactor or a relay);
• central heating system.
Parts supplied:
• one (1) thermostat;
• two (2) mounting screws;
• two (2) solderless connectors suitable for copper
wires.
2. Installation
Selection of thermostat location
The thermostat must be mounted on a connection
box on a wall facing the heating unit, at around 1.5
m (5 feet) above the floor level, on a section of the
wall exempt from pipes or air ducts.
Do not install the thermostat in a location where
temperature measurements could be altered.
For example:
• close to a window, on an external wall, or close to
a door leading outside;
• exposed directly to the light or heat of the Sun, a
lamp, a fireplace or any other heat source;
• close or in front of an air outlet;
• close to concealed ducts or a chimney; and
• in a location with poor air flow (e.g. behind a door), or
with frequent air draft conditions (e.g. head of stairs).
Note:
This handling description is printed prior to product
development. When a part of the product specification
must be changed to improve operability or other func-
tions, priority is given to the product specification it-
self. In such instances, the instruction manual may not
entirely match all the functions of the actual product.
Therefore, the actual product and packaging, as well as
the name and illustration, may differ from the manual.
The screen/LCD display shown as an example in this
manual may be different from the actual screen/LCD
display.