background image

INSSTE402NP0711

8

down the two buttons for more than 10 sec-

onds, until the  

 

 icon displays (note that the  

  icon will also blink after 3 seconds);

3.  Release the buttons. The thermostat is now 

locked.

Deactivating the Security mode

1.  Cut off the power supply of the thermostat at 

the electrical panel;

2.  Wait at least 20 seconds;
3.  Restore the power supply of the thermostat at 

the electrical panel;

4.  The 

 icon is blinking on the thermostat dis-

play, meaning that it is possible to unlock the 

thermostat;

5.  While  the 

 icon is blinking, simultaneously 

press down the two buttons for more than 10 

seconds, until the  

 

 icon disappears;

6.  Release the buttons. The thermostat is now 

unlocked.

NOTE:

 If the thermostat isn’t unlocked within 5 

minutes after the restoration of the power sup-

ply, the  

 

 icon will stop to blink and it will be 

impossible to unlock the thermostat unless cut-

ting off the power supply again.

Heating power indicator

The level of power used to maintain the tempera-

ture at the set point is expressed as a percentage 

indicated by the number of bars in the thermom-

eter displayed. The heating power used is dis-

played as follows:

0 bar = no heat

1 bar = 1% to 25%

2 bars = 25% to 50%

3 bars = 50% to 75%

4 bars = 75% to 100%

Power failure

In the case of a power failure, the adjustments are 

automatically saved and recovered when power 

is restored. Note that the Day/Night mode is re-

covered only if the Smart mode was previously 

deactivated. Otherwise, the thermostat comes 

back in Day mode and the 

 icon blinks, mean-

ing that the Smart mode was previously activated 

and that it is now deactivated. Blinking will stop 

as soon as a button is pressed down.

Содержание STE402NP

Страница 1: ...INSSTE402NP0711 STE402NP Electronic thermostat User s guide www stelpro com For further information or to consult this guide online please visit our Web site...

Страница 2: ...ng installations electrical current higher than 16 7 A with a resis tive load 4000 W 240 VAC 3475 W 208 VAC and 2000 W 120 VAC electrical current lower than 1 2 A with a resistive load 300 W 240 VAC 2...

Страница 3: ...stat does not have polarity Two wire installation Four wire installation 4 Using a screwdriver loosen the screw retaining the mounting base and front part of the thermostat Remove the front part of th...

Страница 4: ...1 4 3 Operation Ambient temperature Timer Modes Frost free Day Night Fan Smart Heating power used indicator Temperature set point Button to decrease set point timer Button to increase set point timer...

Страница 5: ...indi cated on the display by the Sun or Moon icon In order to manually switch from one mode to the other simultaneously press down the two buttons and release them immediately Night mode timer The Ni...

Страница 6: ...ure set point At the end of the 24 hour cycle the thermostat will return to the Night mode and the cycle will start again The 24 hour cycle starts with the Night mode as soon as the Smart mode is acti...

Страница 7: ...the degrees Fahrenheit and conversely The degree Celsius or Fahrenheit symbol will be displayed 3 When the adjustment is completed release the buttons and wait for 5 seconds to exit the ad justment f...

Страница 8: ...5 minutes after the restoration of the power sup ply the icon will stop to blink and it will be impossible to unlock the thermostat unless cut ting off the power supply again Heating power indicator...

Страница 9: ...eating unit has a switch If so ensure that this switch is turned on The display turns off a few minutes and then turns on again The thermal protection of the heating unit has opened due to overheating...

Страница 10: ...it has a 3 year warranty If at any time during this period the unit becomes defective it must be returned to its place of purchase with the invoice copy or simply contact our customer service de partm...

Отзывы: