background image

INSSTE402NP0711

5

Ambient temperature

The figures displayed above the 

 icon indi-

cate the ambient temperature, ± 0.5 degree. 

Temperature can be displayed in degrees Celsius 

or Fahrenheit (see “Display in degrees Celsius/ 

Fahrenheit”).

Temperature set point

The figures displayed above the     icon indicate 

the temperature set point. It can be displayed in 

degrees Celsius or Fahrenheit (see “Display in de-

grees Celsius/Fahrenheit”).
To adjust the set point, just 

press down the right button 

to increase the value, or the 

left button to decrease it. Set 

points can be adjusted by in-

crements of 0.5°C or 1°F. To 

quickly scroll through the set 

point values, press and hold down the button. The 

minimum set point is 3°C (37°F), and the maxi-

mum set point is 30°C (86°F).

In Day mode, you can turn off the thermostat by 

lowering the set point below 3°C. The set point 

value displayed will be --.-, and heating system 

start up will be impossible.

Day mode and Night mode  

The thermostat includes a Day mode and a Night 

mode, both of them having their own indepen-

dently adjustable and recorded set point. When 

switching from one mode to the other, the system 

will automatically use the temperature set point 

corresponding to the Day/Night mode selected. 

The standard factory set point adjustment is 21°C 

for the Day mode, and 18°C for the Night mode.
The current Day/Night mode selection is indi-

cated on the display by the Sun or Moon icon. 

In order to manually switch 

from one mode to the other, 

simultaneously press down 

the two buttons and release 

them immediately.

Night mode timer

The Night mode features a timer that automati-

cally returns to the Day mode after a selectable 

time period. This timer allows the temporary use 

of a temperature set point. The standard factory 

adjustment of the timer is 8 hours. With this ad-

justment, the thermostat automatically returns to 

Day mode 8 hours after being switched to the 

Night mode.

For example, if you want a night temperature 

lower than the day temperature, both Day/Night 

modes set points will first have to be set at the 

desired temperatures. Before bedtime, the Night 

mode temperature set point will be activated by 

switching manually to the Night mode. The timer 

is set for the duration of the night. The thermostat 

will automatically return to the Day mode at the 

end of the night, and the Day mode temperature 

set point, which is higher, will become effective 

at this time.

Night mode timer adjustment procedure

1.  If necessary, adjust the Day/Night mode set 

points at the desired temperatures. If needed, 

switch from one mode to the other by simul-

taneously pressing down the two buttons and 

releasing them immediately.

2.  

From the Night mode, simultaneously press 

down the two buttons for more than 3 seconds 

until the     icon starts to blink, indicating that 

the adjustment of the Night mode timer is effec-

tive. The figures displayed above the 

  icon 

indicate the current adjustment of the timer.

+

-

+

-

+

-

+

-

Содержание STE402NP

Страница 1: ...INSSTE402NP0711 STE402NP Electronic thermostat User s guide www stelpro com For further information or to consult this guide online please visit our Web site...

Страница 2: ...ng installations electrical current higher than 16 7 A with a resis tive load 4000 W 240 VAC 3475 W 208 VAC and 2000 W 120 VAC electrical current lower than 1 2 A with a resistive load 300 W 240 VAC 2...

Страница 3: ...stat does not have polarity Two wire installation Four wire installation 4 Using a screwdriver loosen the screw retaining the mounting base and front part of the thermostat Remove the front part of th...

Страница 4: ...1 4 3 Operation Ambient temperature Timer Modes Frost free Day Night Fan Smart Heating power used indicator Temperature set point Button to decrease set point timer Button to increase set point timer...

Страница 5: ...indi cated on the display by the Sun or Moon icon In order to manually switch from one mode to the other simultaneously press down the two buttons and release them immediately Night mode timer The Ni...

Страница 6: ...ure set point At the end of the 24 hour cycle the thermostat will return to the Night mode and the cycle will start again The 24 hour cycle starts with the Night mode as soon as the Smart mode is acti...

Страница 7: ...the degrees Fahrenheit and conversely The degree Celsius or Fahrenheit symbol will be displayed 3 When the adjustment is completed release the buttons and wait for 5 seconds to exit the ad justment f...

Страница 8: ...5 minutes after the restoration of the power sup ply the icon will stop to blink and it will be impossible to unlock the thermostat unless cut ting off the power supply again Heating power indicator...

Страница 9: ...eating unit has a switch If so ensure that this switch is turned on The display turns off a few minutes and then turns on again The thermal protection of the heating unit has opened due to overheating...

Страница 10: ...it has a 3 year warranty If at any time during this period the unit becomes defective it must be returned to its place of purchase with the invoice copy or simply contact our customer service de partm...

Отзывы: