INSSTCNP15MA0612
It is important to verify the EGFPD installation and operation
on a monthly basis.
EGFPD verification procedure
1- Increase the temperature set point until the heating power
bars are displayed (displayed in the bottom-right hand
corner of the screen).
2- Press down the Test button.
3- The following two cases can occur:
a) Successful test: The red indicator of the thermostat lights
up. In this case, press down once again the Test button to
reinitialize the EGFPD, the red indicator turns off.
b) Failed test: The red indicator does not light up and the
entire display blinks during 5 seconds. In this case, dis-
connect the heating system at the electrical panel and call
Stelpro’s customer service.
Security mode
This mode imposes a maximum temperature set point which
is impossible to exceed regardless of the mode in progress.
However, it is still possible to lower the set point at your
discretion. Please note that when the Security mode is acti-
vated, it is impossible to switch from the
mode to the
mode, and conversely.
Procedures to activate Security mode
1. To activate the Security mode, the thermostat should be in
Day mode. Exit any adjustment mode to manually adjust
the set point at the desired maximum value.
2. Simultaneously press down the + and - buttons during
10 seconds (note that after 3 seconds, the icon starts
to blink and the software version and date are displayed.
Continue to press down these buttons).
3. After 10 seconds, the icon is displayed indicating that
the Security mode is activated. Then, release the buttons.
Procedures to deactivate Security mode
14