INSSTCNP5MA0612
the set point in degrees Celsius (standard factory setting) or
Fahrenheit.
Adjustment procedure for degrees Celsius/Fahrenheit dis-
play.
1. To switch from the degrees Celsius to the degrees Fahren-
heit, and conversely, the thermostat must be from the Day
mode. If so, simultaneously press down the + and - buttons
for more than 3 seconds until the icon blinks.
2. Press down the + button to switch from the degrees Cel-
sius to the degrees Fahrenheit, and conversely. The degree
Celsius or Fahrenheit symbol is displayed.
3. When the adjustment is completed, do not press down any
button during 5 seconds to exit the adjustment function.
/
Mode
To switch from the
mode to the
mode, or conversely,
press down the A
/
F button (when you are not in any adjust-
ment mode). Then, the temperature set point will become the
same as the
or
mode temperature, as applicable.
Safe mode
If the thermostat fails to detect the presence of a floor sensor,
it will automatically revert to
mode at a setpoint of 21°C.
(with a maximum set point temperature of 24°C)
Sensor Selection
If you want to use the STCNP thermostat of Stelpro Design
with a temperature sensor already installed in the floor (other
than the sensor supplied with this thermostat), you must con-
tact the Stelpro Design customer service to validate the com-
patibility between the sensor and the thermostat. You must
know the serial number and name of the installed sensor.
Temperature Control
The thermostat controls the
/
temperature (accord-
12