At the first start-up, the thermostat is initially in the Day and
modes. The temperature is displayed in degrees Celsius
and the standard factory set point adjustment is 25°C. The
maximum floor temperature is limited to 28°C.
Maximum floor temperature limitation
At any time, the floor temperature (both in
and
modes)
is maintained at less than 28°C (82°F) in order to avoid over-
heating caused by an excessive heating request, which could
damage some materials or be detrimental for health.
Temperature set points
The figures beside the icon indicate the temperature set
points (both in
and
modes). They can be displayed in
degrees Celsius or Fahrenheit (see “Display in degrees Cel-
sius/Fahrenheit”).
Out of any adjustment mode, press down the + button to in-
crease the set point, or the - button to decrease it. Set points
can only be adjusted by increments of 1 degree. To quickly
scroll through the set point values, press and hold down the
button. Both in Manual and Smart modes, the
mode set
points can range between 3 and 35°C and can only be ad-
justed by increments of 1°C (from 37 to 95°F; by increments
of 1°F from the Fahrenheit mode). From
mode, the set
points can range between 3 and 28°C (from 37 to 82°F).
In Day mode, you can turn off the thermostat by lowering the
set point below 3°C (37°F). The set point value displayed will
be --, and heating system start up will be impossible.
Day mode and Night mode
8