background image

3

INSELN0418

ELECTRICITY:

TURN OFF THE POWER BEFORE CONNECTING THE UNIT

Check if the power supply corresponds to that indicated on the nameplate.
Connect the dryer to a bypass circuit according to electrical and building codes in your area.
Connect the power cable to the terminals of the hand dryers, as shown in the wiring diagram inside the cover of the dryer.
Do not forget to connect the ground wire to the ground cover on the terminal available at the motor base.
If the hand dryer is located in a shower or in other wet locations, it shall be protected by a ground fault circuit breaker.

Note:  : 

When installing on a gypsum wall, ensure that at least two anchor bolts are set in a beam of wood or steel. Where possible, it is 

recommended to install a wooden beam behind the gypsum (see # 3). If the other 2 screws must be fixed in a hollow wall, use ¼” wing type 

through bolts.

HOW TO REMOVE THE COVER OF THE HAND DRYER: (1-2-3)

Screw the two screws of the cover using the key supplied with each unit, slide the cover up, then tilt it backward to remove it.

FIG. 1

FIG. 2

FIG. 3

HOW TO REPLACE THE COVER OF THE HAND-DRYER: EXECUTE STEPS IN REVERSE (3-2-1)

Fully insert the cover of the air outlet by tilting it, replace the cover on the housing and slide it down so that it clings to its support, then secure it 

by removing the 2 screws.
Check the serial number inside the hand-dryer before replacing the cover to ensure it matches the serial number at the bottom of the cover. DO 

NOT SWITCH COVERS OF THE UNITS.

FIG. 1

FIG. 2

Determine the location of the hand dryer and cut out a wall opening to the suggested dimensions.
Bring the power cable into the installation hole.

RECESSED INSTALLATION

FLOOR

minimum 15 " (see table)

8 7/16

214mm

9 7/8

251mm

Содержание EL-NINO

Страница 1: ...lling repairing and cleaning the unit Make sure the unit is appropriate for the intended use if needed refer to the product catalog or a representative Do not install the unit where objects or pieces...

Страница 2: ...structions poses a fire hasard Thermal protection activation indicates that the unit has been subjected to abnormal operating conditions If the thermal protection remains activated or activates and de...

Страница 3: ...behind the gypsum see 3 If the other 2 screws must be fixed in a hollow wall use wing type through bolts HOW TO REMOVE THE COVER OF THE HAND DRYER 1 2 3 Screw the two screws of the cover using the ke...

Страница 4: ...NSTALLATION FLOOR minimum 15 see table 7 178mm REINFORCEMENT STUD FIG 3 FIG 4 FIG 5 FIG 3 FIG 1 FIG 4 FIG 2 FIG 5 Determine the location you want the hand dryer and screw the two top anchor screws as...

Страница 5: ...st savings HARMONY Reduced air speed without heat for energy savings and a moderate noise level THREE SENSITIVITY DETECTIONS DESCRIPTION AND SYMBOL Maximal detection standard 4 Medium detection decrea...

Страница 6: ...t or other internal parts of dryer will reduce efficiency and shorten the life of the working parts To clean remove cover by screwing the tamper proof bolts from cover with the special wrench provided...

Страница 7: ...ADAPTER WHITE ELN 004BC SURFACE ADAPTER BRUSHED CHROME 3 MO 79 120V 50 60HZ 130CFM MO 80 208V 50 60HZ 130CFM MO 81 240V 50 60HZ 130CFM 4 ELF ELN0901 HEATING ELEMENT ASSEMBLY 120 V 900 W 5 CIR 033 ELEC...

Страница 8: ...damages damages for lost profits loss of use of equipment cost of capital cost of substitute products facilities or services shutdowns slowdowns or for other types of economic loss or for claims of a...