INSELN0418
ELECTRICITY:
TURN OFF THE POWER BEFORE CONNECTING THE UNIT
Check if the power supply corresponds to that indicated on the nameplate.
Connect the dryer to a bypass circuit according to electrical and building codes in your area.
Connect the power cable to the terminals of the hand dryers, as shown in the wiring diagram inside the cover of the dryer.
Do not forget to connect the ground wire to the ground cover on the terminal available at the motor base.
If the hand dryer is located in a shower or in other wet locations, it shall be protected by a ground fault circuit breaker.
Note: :
When installing on a gypsum wall, ensure that at least two anchor bolts are set in a beam of wood or steel. Where possible, it is
recommended to install a wooden beam behind the gypsum (see # 3). If the other 2 screws must be fixed in a hollow wall, use ¼” wing type
through bolts.
HOW TO REMOVE THE COVER OF THE HAND DRYER: (1-2-3)
Screw the two screws of the cover using the key supplied with each unit, slide the cover up, then tilt it backward to remove it.
FIG. 1
FIG. 2
FIG. 3
HOW TO REPLACE THE COVER OF THE HAND-DRYER: EXECUTE STEPS IN REVERSE (3-2-1)
Fully insert the cover of the air outlet by tilting it, replace the cover on the housing and slide it down so that it clings to its support, then secure it
by removing the 2 screws.
Check the serial number inside the hand-dryer before replacing the cover to ensure it matches the serial number at the bottom of the cover. DO
NOT SWITCH COVERS OF THE UNITS.
FIG. 1
FIG. 2
Determine the location of the hand dryer and cut out a wall opening to the suggested dimensions.
Bring the power cable into the installation hole.
RECESSED INSTALLATION
FLOOR
minimum 15 " (see table)
8 7/16
214mm
9 7/8
251mm