background image

Stellar Pump Australia  

 
 
 
 
 

 

Installation, Operation and Maintenance (IOM) Manual 

Extreme hazard which will 

result of severe injury or 

death 

Hazard which could result 

of personal injury or 

severe damage to 

property 

Hazard which could result 

of minor injury or damage 

to property 

 
 

 
TABLE OF CONTENTS: 
 

Section I: Introduction 

 

 

------------------------------------------------------------------------------ Page 3 

 

 

Section II: General Practice  

 

------------------------------------------------------------------------------ Page 4 

 

 

Section III: Warranty 

 

 

------------------------------------------------------------------------------ Page 4 

 
Section IV: Storage & Lifting 

 

------------------------------------------------------------------------------ Page 4 

 

 

Section V: Installation 

 

 

------------------------------------------------------------------------------ Page 5 

 
Section VI: Operation Procedure 

 

------------------------------------------------------------------------------ Page 5 

 
Section VII: Maintenance Procedure 

------------------------------------------------------------------------------ Page 7 

 
Section VIII: Spare Parts   

 

------------------------------------------------------------------------------ Page 9 

 
Section IX: Exploded View  

 

----------------------------------------------------------------------------- Page 11 

 
Section X: Trouble Shooting 

 

----------------------------------------------------------------------------- Page 14 

 
 

 
SECTION I: INTRODUCTION  

 
STELLAR PUMP HESC series horizontal end suction close-coupled pump, HESB series horizontal end suction bare 
shaft pump and VISC series Vertical in-line single stage pump are manufactured with same performance where 
impeller is interchangeable to other series. Thus, this Installation, Maintenance and Operation (IOM) manual is 
applicable to HESB series, HESC series and VISC Series.  
 
This IOM Manual shall be read entirely prior for installation and operation. Stellar Pump shall not be liable for 
any injuries, damages & pertaining cost due to failure in observing the instructions and maintenance contained 
in this manual.  
 
The following symbols indicated in this manual are needed to pay attention: 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 

Содержание HESB Series

Страница 1: ...llation Operation Maintenance Manual HESC Series Horizontal End Suction Close Coupled Pump HESB Series Horizontal End Suction Bare Shaft Pump VISC Series Vertical In Line Singe Stage Pump HESC Pump HE...

Страница 2: ...umbers are not on the list it means The list is not yet updated quarterly updating the Authentic page It has been removed to accommodate newly registered serial numbers The product s that you have rec...

Страница 3: ...X Exploded View Page 11 Section X Trouble Shooting Page 14 SECTION I INTRODUCTION STELLAR PUMP HESC series horizontal end suction close coupled pump HESB series horizontal end suction bare shaft pump...

Страница 4: ...of this pump SECTION III WARRANTY CONDITION This warranty applies against all defective materials and or faulty manufacture for the period of One 1 year from the date of shipment unless specifically s...

Страница 5: ...or plinth as long as surface is properly level b Pump can be installed with rubber isolation spring isolation or inertia base to avoid transfer of vibration during operation Kindly refer to manufactu...

Страница 6: ...f wires and cables for electric motor shall be in accordance to related electrical code local regulations b Wire or cable sizes must be appropriate to Kilowatt kw or Horsepower hp rating of electric m...

Страница 7: ...erature vibration could damage the ceramic coating of mechanical seal ii Presence of solid particles in water could also damage the mechanical seal iii Misalignment of pump and or motor shaft could al...

Страница 8: ...o overheat c Bearings should be replaced every 10000 working hours 3 Mechanical Seal a Presence of high temperature in pump volute excessive vibration and poor quality of water will damage the ceramic...

Страница 9: ...C Series Horizontal End Suction Close Coupled Pump a Intermittent duty Item Description 5 5 1 Front and back wear ring 8 Set of Mechanical Seal 4 Casing Gasket Refer to Section IX for reference b Cont...

Страница 10: ...il Seal 33 Bushing gasket Refer to Section IX for reference If type of seal is mechanical If type of seal is packing gland 3 Recommended Spare Parts for VISC Series Vertical In line Single Stage Pump...

Страница 11: ...n 1 Pump Casing 2 Plug 2 1 Plug Spacer 3 Nut 3 1 Flat Washer 3 2 Spring Washer 4 Casing Gasket 5 Front Wear Ring 5 1 Back Wear Ring 6 Impeller 7 Seal Seat 8 Mechanical Seal 9 Casing Cover 10 Adapter I...

Страница 12: ...er 10 Bearing Housing 11 Shaft 12 Bearing 13 Bearing Cover Item Description 14 Support 14 1 Flat Washer 14 2 Elastic Washer 14 3 Screw Bolt 15 Packing Sleeves 16 Packing Seal Cage 17 Packing Gland 18...

Страница 13: ...scription 1 Pump Casing 2 Impeller Nut 3 Flat Washer 4 Spring Washer 5 Front Wear Ring 6 Impeller 7 Seal Seat 8 Mechanical Seal 9 Casing Gasket 10 Casing Cover 11 1 4 Plug 12 Adapter 13 Guard 14 Screw...

Страница 14: ...s motor HP 6 Remove solid particles 7 Replace wear ring Excessive noise and vibration 1 Trap air or leak at suction pipe 2 Impeller direction wrong 3 Misalignment 4 Bearings operating dry condition 1...

Отзывы: