Installation, Operation and Maintenance (IOM) Manual 

 

b.

 

Floor of pump room or storage should be dry, free from any stagnant water for avoid certain 
accidents.  

c.

 

No moisture or humidity exists inside the pump room or storage. Necessary ventilation system 
is required.  

d.

 

Pump room or storage must be secured, free from any thieves and trespassers. Only 
authorized personnel or maintenance should have an access inside.  

 

 
 
 

e.

 

Shut down all power supply when performing maintenance routine to avoid certain accidents.  

f.

 

Wear Personal Protective Gear or Equipment before performing maintenance check.  

g.

 

It is highly recommended to update regularly the maintenance record for future reference.  
 

2.

 

Bearings 

a.

 

Bearings are not allowed to operate higher than 70

o

C. Inspect the bearings if temperature is 

not within the normal ranges.  

b.

 

 Lubricate bearings using calcium based grease or SAE20W Oil. Pumps in 2 pole speed 
(2900rpm in 50hz or 3500rpm in 60hz) should replenish oil or grease every 2500 working 
hours. 4 pole speed (1450rpm in 50hz or 1750rpm in 60hz) should replenish oil or grease 
every 5000 working hours. Do not over lubricate because it will cause to overheat.  

c.

 

Bearings should be replaced every 10000 working hours. 
 

3.

 

Mechanical Seal 

a.

 

Presence of high temperature in pump volute, excessive vibration and poor quality of water 
will damage the ceramic coating of mechanical seal.   

b.

 

Mechanical seals should be replaced immediately if leakage found during standby and running 
operation.  

 

4.

 

Packing Gland Seal 

a.

 

There should be water droplet in packing gland seal during in running operation. Standard 
drop ranges from 50 to 70 droplets in every minute.  

b.

 

Adjust packing gland cover by adjusting the bolts if water droplets is exceeded in standard 
ranges. 

c.

 

Packing gland is consumable or subject for wear & tear depending on operation. Replace the 
packing gland if water droplet exceeded to its standard ranges even though packing gland 
cover has been adjusted accordingly. 
 

5.

 

Electrical Conditions  

 
 
 
 

a.

 

Power voltage fluctuations 

i.

 

To maintain the expected life period, do not operate the electric motor if 

1.

 

Actual voltage fluctuates beyond tolerance bands of +/- 10% from normal 
power voltage. 

2.

 

Actual voltage fluctuates within tolerance bands of +/- 10% from normal 
power voltage for more than 60 minutes each day.  

ii.

 

Electric components for protection against abnormal fluctuation of power supply 
voltage or to maintain the stability of power supply voltage for entire day is required 
to avoid premature damage of electric motor.  
 

 

Содержание HESB Series

Страница 1: ...llation Operation Maintenance Manual HESC Series Horizontal End Suction Close Coupled Pump HESB Series Horizontal End Suction Bare Shaft Pump VISC Series Vertical In Line Singe Stage Pump HESC Pump HE...

Страница 2: ...umbers are not on the list it means The list is not yet updated quarterly updating the Authentic page It has been removed to accommodate newly registered serial numbers The product s that you have rec...

Страница 3: ...X Exploded View Page 11 Section X Trouble Shooting Page 14 SECTION I INTRODUCTION STELLAR PUMP HESC series horizontal end suction close coupled pump HESB series horizontal end suction bare shaft pump...

Страница 4: ...of this pump SECTION III WARRANTY CONDITION This warranty applies against all defective materials and or faulty manufacture for the period of One 1 year from the date of shipment unless specifically s...

Страница 5: ...or plinth as long as surface is properly level b Pump can be installed with rubber isolation spring isolation or inertia base to avoid transfer of vibration during operation Kindly refer to manufactu...

Страница 6: ...f wires and cables for electric motor shall be in accordance to related electrical code local regulations b Wire or cable sizes must be appropriate to Kilowatt kw or Horsepower hp rating of electric m...

Страница 7: ...erature vibration could damage the ceramic coating of mechanical seal ii Presence of solid particles in water could also damage the mechanical seal iii Misalignment of pump and or motor shaft could al...

Страница 8: ...o overheat c Bearings should be replaced every 10000 working hours 3 Mechanical Seal a Presence of high temperature in pump volute excessive vibration and poor quality of water will damage the ceramic...

Страница 9: ...C Series Horizontal End Suction Close Coupled Pump a Intermittent duty Item Description 5 5 1 Front and back wear ring 8 Set of Mechanical Seal 4 Casing Gasket Refer to Section IX for reference b Cont...

Страница 10: ...il Seal 33 Bushing gasket Refer to Section IX for reference If type of seal is mechanical If type of seal is packing gland 3 Recommended Spare Parts for VISC Series Vertical In line Single Stage Pump...

Страница 11: ...n 1 Pump Casing 2 Plug 2 1 Plug Spacer 3 Nut 3 1 Flat Washer 3 2 Spring Washer 4 Casing Gasket 5 Front Wear Ring 5 1 Back Wear Ring 6 Impeller 7 Seal Seat 8 Mechanical Seal 9 Casing Cover 10 Adapter I...

Страница 12: ...er 10 Bearing Housing 11 Shaft 12 Bearing 13 Bearing Cover Item Description 14 Support 14 1 Flat Washer 14 2 Elastic Washer 14 3 Screw Bolt 15 Packing Sleeves 16 Packing Seal Cage 17 Packing Gland 18...

Страница 13: ...scription 1 Pump Casing 2 Impeller Nut 3 Flat Washer 4 Spring Washer 5 Front Wear Ring 6 Impeller 7 Seal Seat 8 Mechanical Seal 9 Casing Gasket 10 Casing Cover 11 1 4 Plug 12 Adapter 13 Guard 14 Screw...

Страница 14: ...s motor HP 6 Remove solid particles 7 Replace wear ring Excessive noise and vibration 1 Trap air or leak at suction pipe 2 Impeller direction wrong 3 Misalignment 4 Bearings operating dry condition 1...

Отзывы: