Lifting with hoist and strap 

Lift  the  machine  by  using  ONLY  both  handles  as 
shown on the picture. 
Keep the machine as horizontal as possible 
 
 

 

 

 
 
INSTRUCTION FOR 
INSECURE POSITIONING 

Failure  to  properly  secure  the  machine  can  cause 
personal injury. 
If machine is in an insecure position do not attempt 
to switch on. 
Do  not  put  the  machine  on  an  unlevelled  surface 
greater than 10°. 

 
FRONT PANEL DESCRIPTION 
 

 

Machine live led 

Welding enabled  

Over temperature led 

Button Voltage View 

Voltage Led 

Encoder for regulating Arc Force /  
Slope Down / Inductance 

Encoder for regulating welding current 

Button for Welding Mode Selection  

Mig CV Mode  Warning Led 

10 

Mig CC Mode  Warning Led 

11 

Tig Lift Mode  Warning Led 

12 

Electrode Mode  Warning Led 

 
 
 
 
 
 
 

SUB MENU 
- HOT START 

HOT START ADJUSTMENT 

1) Switch on the welding machine.  
2) Hold down the button 

“SELECT MODE”

 on the 

front  panel  of  the  machine  for  about  2  seconds, 
then  release  the  button;  the  warning  led  of  the 
selected  mode  will  blink  and  the  display  will  show 
HS.  Now  you  can  adjust  the  hot  start  from  0  to 
50% of the selected welding current with encoder 

6

 

(max 400A). 
 

- V.R.D. 

(AVAILABLE ONLY IN 

MMA

 MODE) 

V.R.D. MANAGEMENT 

The 

initials 

V.R.D. 

stand 

for 

VOLTAGE 

REDUCTION  DEVICE,  which  is  a  system  for 
reducing  the  no-load  voltage  (OCV).  When  the 
V.R.D. is installed in a welding machine it reduces 
the  maximum  no-load  voltage  to  a  safety  voltage 
which is normally less than 18V. 
-  The  V.R.D.  is  used  as  an  additional  aid  for 
operator safety. 
- The procedures for safety at work must always be 
carried out with attention. 

 
ACTIVATE  V.R.D. 

1) Switch on the welding machine.  
2)  Hold  down  button 

4

  on  the  front  panel  of  the 

machine  for  about  4  seconds,  then  release  the 
button;  the  welding  enable  led 

2

  blinks    (V.R.D. 

FUNCTION ON)   ( V out 18V).VRD mode remains 
activated  when  switching  the  machine  off  and  on 
again. 
 

DEACTIVATE  V.R.D. 

1) Switch on the welding machine.  
2)  Hold  down  button 

4

  on  the  front  panel  of  the 

machine  for  about  4  seconds,  then  release  the 
button; the welding enable led 

2

 remains lit with a 

fixed  light  (V.R.D.  FUNCTION  deactivated).  VRD 
mode  remains  deactivated  when  switching  the 
machine off and on again. 

 
- CC/CV (SUITCASE FEEDER) 

With  this  function  the  MAX  403/403S  is  able  to 
connect  and  then  operate  together  with  any 
suitcase  feeder.  Please  select 

CV 

Mode  on  the 

front panel. 

 

Содержание Max 403

Страница 1: ...NUALE DI ISTRUZIONE PER SALDATRICE INSTRUCTION MANUAL FOR WELDING MACHINE BETRIEBSANLEITUNG FÜR SCHWEIßERÄTE MAX 403 MAX 403 MAX 403 MAX 403 MAX MAX MAX MAX 403S 403S 403S 403S Info www stelgroup it tel 39 0444 639525 ...

Страница 2: ...zed standard in force within the EEA has been used in the design EN 60974 1 Arc welding equipment Part 1 Welding power sources EN 60974 10 Arc welding equipment Part 10 Electromagnetic compatibility EMC requirements EN 61000 3 12 Arc welding equipment Part 10 Electromagnetic compatibility EMC requirements Only For Max 403S Additional information Restrictive use Class A equipment intended for use i...

Страница 3: ...A SALUTE Tenere il capo fuori dalla portata dei fumi Provvedere per una ventilazione adeguata dell area di lavoro Se la ventilazione non è sufficiente usare un aspiratore che aspiri dal basso IL CALORE GLI SCHIZZI DEL METALLO FUSO E LE SCINTILLE POSSONO PROVOCARE INCENDI Non saldare vicino a materiali infiammabili Evitare di portare con sé qualsiasi tipo di combustibile come accendini o fiammiferi...

Страница 4: ...olla ed ottimizza il trasferimento dell arco indipendentemente dalla variazione del carico e dell impedenza dei cavi di saldatura I comandi sul pannello frontale consentono una facile programmazione delle sequenze di saldatura in funzione delle esigenze operative La tecnologia inverter usata ha permesso di ottenere generatori con peso e dimensioni estremamente contenuti ridotto consumo energetico ...

Страница 5: ...sicurata dal ventilatore interno Evitare che i ventilatori immettano nella macchina depositi o polveri E bene evitare urti sfregamenti ed in maniera assoluta l esposizione a stillicidi fonti di calore eccessive o comunque situazioni anomale TENSIONE DI RETE Il generatore funziona con queste tensione di alimentazione MAX 403S 190V 575V 3P MAX 403 400V 3P 10 e Fuse rating di MAX 403S 40 A Fuse MAX 4...

Страница 6: ...one 6 si puo variare il valore di sovracorrente temporanea da 0 al 50 rispetto alla corrente di saldatura impostata max 400A V R D ATTIVO SOLO IN ELETTRODO GESTIONE V R D La sigla V R D sta per VOLTAGE REDUCTION DEVICE che non è altro che un sistema per la riduzione della tensione a vuoto Quando si installa il V R D in una saldatrice esso riduce la tensione a vuoto massima ad una tensione di sicur...

Страница 7: ...pare casualmente sul display verificare la connessione con gli accessori esterni il sistema di messa a terra e la configurazione dell area di lavoro DUTY CYCLE E SOVRATEMPERATURA Se il LED n 3 e accesso e sul display appare la la dicitura HT 1 3 5 7 fissa 1 Il generatore ha superato il ciclo di intermittenza dichiarato Il ciclo di intermittenza è la percentuale di utilizzo della saldatrice su 10 m...

Страница 8: ...triche ed elettroniche e relativa attuazione nell ambito della legislazione nazionale le apparecchiature elettriche giunte a fine vita devono essere raccolte separatamente e conferite ad un impianto di riciclo ecocompatibile In qualità di proprietario delle apparecchiature dovrà informarsi presso il nostro rappresentante in loco sui sistemi IN CASO DI CATTIVO FUNZIONAMENTO RICHIEDETE L ASSISTENZA ...

Страница 9: ...cause burns Keep the tip of the electrode far from your body and from other persons PREVENTION OF ELECTRIC SHOCKS Take the following precautions when working with a welding machine keep yourself and your clothes clean do not be in contact with damp or wet parts when working with the welding machine maintain suitable insulation against electric shock If the operator has to work in a damp environmen...

Страница 10: ...g of the welding sequences depending on the operating requirements The inverter technology used has allowed the following to be obtained machines with extremely low weight and compact dimensions reduced energy consumption excellent dynamic response very high power factor and yields better welding characteristics viewing of the data and of the set functions on the display The electronic components ...

Страница 11: ...chine in such a way that there is no obstacle to the air circulation ensured by the internal fan since the internal components require suitable cooling Ensure that the fan does not send deposits or dust into the machine Avoid impacts rubbing and absolutely no exposure to dripping water excessive heat sources or any abnormal situations MAINS VOLTAGE The machine operates from the following mains sup...

Страница 12: ...rom 0 to 50 of the selected welding current with encoder 6 max 400A V R D AVAILABLE ONLY IN MMAMODE V R D MANAGEMENT The initials V R D stand for VOLTAGE REDUCTION DEVICE which is a system for reducing the no load voltage OCV When the V R D is installed in a welding machine it reduces the maximum no load voltage to a safety voltage which is normally less than 18V The V R D is used as an additional...

Страница 13: ...heck tha all accessories to the work piece from the power source especially including earthing are secure and not damaged DUTY CYCLE AND EXCESSIVE TEMPERATURE The Led indicator light 3 is ON and the A LED displays HT 1 3 5 7 1 This is indicating the unit has exceeded the Duty Cycle The duty cycle is the percentage of use of the welding machine in 10 minutes which the operator must respect to avoid...

Страница 14: ...cordance with national law electrical equipment that has reached the end of its life must be collected separately and returned to an environmentally compatible recycling facility As the owner of the equipment you should get information on approved collection systems from our local representative By applying this European Directive you will improve the environment and human health IN CASE OF MALFUN...

Страница 15: ...ine entflammbaren Dinge mit sich wie Feuerzeuge oder Streichhölzer Der Lichtbogen kann Brände verursachen Halten Sie die Spitze der Elektrode von Ihrem Körper sowie von Personen in Ihrer Nähe fern VORSICHTSMASSNAHMEN UM EINEN ELEKTROSCHOCK ZU VERHINDERN Treffen Sie folgende Vorkehrungen wenn Sie mit einem Schweißgerät arbeiten Halten Sie sich und Ihre Kleidung sauber Berühren Sie keine feuchten od...

Страница 16: ...len Die Mikroprozessorschaltung steuert und optimiert den Transfer des Lichtbogens ungeachtet der Lastschwankung und des Schweißkabelwiderstands Die Steuerung an der Frontplatte ermöglicht ein einfaches Programmieren der Schweißfolge in Abhängigkeit der Arbeitsanforderungen Die eingesetzte Inverter Technologie ermöglicht folgende Punkte Maschinen mit extrem geringem Gewicht und kompakten Abmessung...

Страница 17: ...nschaft und private Netzwerk Niedervolt System angeschlossen werden Die gute Bedienung der Maschine wird durch fachgerechte Montage gewährleistet deshalb müssen Sie wie folgt vorgehen Stellen Sie das Gerät so auf dass nichts die Luftzirkulation die durch den eingebauten Lüfter gesichert wird behindert Die inneren Bauteile benötigen eine ausreichende Kühlung Stellen Sie sicher dass der Lüfter keine...

Страница 18: ...steht unter Spannung 2 Led Anzeige Schweißen aktiv 3 Led Anzeige Übertemperatur 4 Knopf Spannungsanzeige 5 Led Anzeige Spannung 6 Encoder zur Regulierung der Lichtbogenstärke Slope down Induktivität 7 Encoder zur Regulierung des Schweißstroms 8 Knopf zur Wahl des Schweißmodus 9 Led Anzeige Mig CV Modus 10 Led Anzeige Mig CC Modus 11 Led Anzeige Tig Lift Modus 12 Led Anzeige Elektroden Modus UNTERM...

Страница 19: ...rontbplatte für MIG Schweißen FEHLERHAFTE PF0 1 Unter normalen Bedingungen zeigt MAX 403S PF0 in A LED nach dem Einschalten Das PFC System erkennt nun die Eingangsspannung Dieser Prozess benötigt ca 3 4 sec nach dem Einschalten 2 Wenn PF0 bleibt oder blinkt PF0 dies ist ein Ergebnis des PFC Systems blockiert werden Rückgabe der Maschine zur Reparatur oder Reparatur durch einen qualifizierten Servi...

Страница 20: ...er der PC Karten möglicherweise fehlerhaft ist Rückgabe der Maschine zur Reparatur oder Reparatur durch einen qualifizierten Service Techniker Laut Betriebsanleitung ENTSORGUNG VON ELEKTRISCHEN UND ELEKTRONISCHEN GERÄTEN Entsorgen Sie keine elektrischen Geräte zusammen mit normalem Müll Gemäß Europäischer Richtlinie 2002 96 EG über Elektro und Elektronik Altgeräte und Umsetzung in nationales Recht...

Страница 21: ...6932300010 21 WIRING DIAGRAM MAX 403 WIRING DIAGRAM MAX 403S ...

Страница 22: ...6932300010 22 EXPLODED VIEW MAX 403 EXPLODED VIEW MAX 403S ...

Страница 23: ...4781000 61282800 65077500 61282700 6611570L 620586CG 66103400 61307300 66118200 66118100 66116200 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 Front Panel Frame Knob Grid Front Label Front Panel Socket Remote Female Conn Socket Foot Front Fan Lem probe Primar...

Страница 24: ... Data Reception Serial Gate B Common Communication Serial Gate C Data Transmissions Serial Gate D Data Transmissions Serial Gate Speed Motor E Data Reception Serial Gate Speed Motor H Positive connection Welding Voltage I Negative connection Welding Voltage TYPE CONNECTION PIN DECSRIPTION EARTH CLAMP A NEGATIVE ELECTRODE B POSITIVE MMA POSSIBLE REMOTE C PIN TYPE CONNECTION PIN DECSRIPTION TIG TORC...

Страница 25: ...E The Hot start supplies a extra current upon starting which allows the electrode to be immediately removed and promptly begin welding The Hot Start is adjustable HOT START 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 time Current extra energy IDEAL SETTING ELECTRODE TYPE DIAMETER CURRENT HOT START ARC FORCE 6013 2 5 80 10 0 RUTILE 6013 3 25 115 10 0 7018 2 5 90 10 1...

Страница 26: ...6932300010 26 Info www stelgroup it tel 39 0444 639525 ...

Отзывы: