6932300010
11
a) IDENTIFICATION
Name, address of the manufacturer
Type of welding machine
Identification with reference to serial number
Symbol of the type of welding machine
Reference to the construction standards
b) WELDING OUTPUT
Symbol of the work process
Symbol for welding machines suitable for working in
an environment with a high risk of electric shock.
Symbol of the welding current
Assigned no-load voltage (operating voltage)
Range of the welding current
Values of the intermittence cycle (in 10 minutes)
Values of the assigned welding current
Values of the conventional loaded voltage
c) POWER SUPPLY
Power supply symbol (number of phases and
frequency)
Assigned power supply voltage
Maximum power supply current
Maximum effective power supply current (identifies
the line fuse)
d) OTHER CHARACTERISTICS
Degree of protection .
INSTALLATION
INSTALLATION
WARNING: This
Class A
equipment is not
intended for use in residential locations where the
electrical power is provided by the public low-
voltage supply system. There may be potential
difficulties in ensuring electromagnetic compatibility
in those locations, due to conducted as well as
radiated disturbances. The MAX 403 equipment is
NOT
in compliance with IEC
61000-3-12
In the event the equipment is connected to a
municiple low voltage network, it is the
responsibility of the operator or electrical
technician, that they may want to consult first with
the local Municipality prior to connecting the
equipment. The MAX 403S is in compliance with
IEC 61000-3-12.
Therefore the equipment can be
connected to a municiple low voltage network
without issue. Correct installation is important for
the good operation and performance of the
machine, you must therefore proceed as follows:
- Position the machine in such a way that there is
no obstacle to the air circulation ensured by the
internal fan since the internal components require
suitable cooling.
- Ensure that the fan does not send deposits or
dust into the machine.
- Avoid impacts, rubbing, and – absolutely no
exposure to dripping water, excessive heat
sources, or any abnormal situations.
MAINS VOLTAGE
The machine operates from the following mains
supply voltage(s):
MAX 403S
190V-575V 3Phase
MAX 403
400V 3Phase +/- 10%
with a Fuse rating of
MAX 403S
40 A Fuse
MAX 403
32 A Fuse
CONNECTION
- Before making the electrical connections between
the welding machine and the line switch, ensure
that the switch is turned off .
- The distribution panel must comply with the
regulations in force in the country of use.
- The mains system must be of the industrial type.
- For longer connecting cables, increase the lead
section as required.
- When using long extension cables, the cable core
diameter size is relevant to the machine
requirements for achieving optimum performance.-
- The power input supply socket from the mains
voltage supply, must have a suitable switch
provided together with a 'slow-burning' type
fuse(s).
- In the event of damage to the power cable,
replacement or repair must be performed by a
qualified person at an approved service centre.
EARTHING
- To ensure user protection the welding machine
must absolutely be correctly connected to the earth
system
(INTERNATIONAL
SAFETY
REGULATIONS).
- It is indispensable to provide good earthing by
means of the yellow-green lead in the power cable,
in order to avoid discharges due to accidental
contacts with earthed objects .
- The chassis (which is conductive) is electrically
connected with the earth lead; if the equipment is
not suitably connected to earth it may cause
electric shocks which are dangerous for the user.
LIFTING
WARNING
:
The machine weighs 35 kg / 77 lb (MAX 403).
The machine weighs 40 kg / 88 lb (MAX 403S)
Lifting by hand:
Lift the machine using the two handles provided
.