Use Notices                                                                                                    NYMCS-603

 

 
I

Safety  note

 

1.    Carefully  open the box, avoid the accessories,  like lens, dropping  to ground and being damaged. 

2.    Do  keep  the  instrument   out  of  direct  sunlight,  high  temperature   or  humidity,   dusty  and  easy 

shaking  environment.  Make sure the stage is smooth,  horizontal  and firm enough. 

3.    When  moving  the  instrument,  please  use  two  hands  to  grip  with  the  two  sides  of  the microscope 

body. 

4.    If  the  bacterium  solution  or  the  water  splash  to  the  stage,  objective  or  viewing  tube,  pull  out the 

power cord at once, and wipe up the microscope.  Otherwise,  the instrument  will be damaged. 

5.    When  running,  the  lamp  house  and  nearby  parts  will  be  very  hot.  Please  ensure  there  is  enough 

cooling  room for them. 

6.    Make sure the instrument  is earthed,  to avoid  lighting  strike. 

7.    For safety,  be sure the main switch  is in “O” (off)  state before  replace  the halogen  lamp or the fuse, 

then  cut  off  the  power,  and  do  the  operation  after  the  lamp  bulb  and  the  lamp  house  completely  cool. 

8.    Check  the  input  voltage:  be  sure  the  input  voltage  which  signed  in the  back  of  the microscope  is 

consistent  with the power supply  voltage,  or it will bring a serious  damage  to the instrument. 

9.    Use the factory supplied  power cord, please. 

 
II

Maintenance

 

1.       All the lenses have been well checked  and adjusted.  It is forbidden  to disassemble  them  yourself. 

2.       The  nosepiece   and  coarse/fine   focus   unit  have  a  compact   and  precise   frame,   please  don’t 

disassemble  them as possible  as you can. 

3.       Keep the  instrument c lea n, wipe dust regularly, and  be  attention to  avoid contaminating the 

optical  elements  especially. 

4.      

The contaminations  on the prism,  as finger  mark and oil, could be gently wiped with a piece of soft 

cloth or tissue paper, gauze which  has been immersed  in pure alcohol or xylene. 

(Note that the alcohol 

and the xylene are all burned  easily, do not let them near the fire, and use them in a drafty room as 

possible  as you can.)

 

5.       Don’t use organic  solvent  to wipe the non-optical  elements,  when  you need to clean,  use the soft 

detergent,  please. 

6.       When  using,  if  the  microscope  is  splash  by  liquid,  cut  off  the  power  at  once,  and  wipe  up  the 

moisture. 

7.       Do  not  disassemble any  parts  of  the  microscope.  That  will  affect  the  function or decline the 

performance  of the microscope. 

8.       Place  the  instrument  in  a  cool,  dry  position.  After  using  the  microscope, remember  to  cover  it 

with dust helmet.  Do wait for the lamp house cooling  completely  before  cover. 

 
 
 
 
 

Содержание NYMCS-603

Страница 1: ...r Manual This manual is written for Metallurgical Microscope of NYMCS 603 For safety and for exerting the best performance making you familiar with the instrument entirely it is strongly recommended t...

Страница 2: ...Notices 2 1 Components Name 3 2 Installation 4 2 1 Installing Diagram 4 2 2 Installing steps 5 3 Adjustment Operation 9 3 1 Adjustment System Installing Illustration 9 3 2 Operation 11 4 Technical Sp...

Страница 3: ...pply voltage or it will bring a serious damage to the instrument 9 Use the factory supplied power cord please II Maintenance 1 All the lenses have been well checked and adjusted It is forbidden to dis...

Страница 4: ...3 STEINDORFF 1 Name of Components NYMCS 603...

Страница 5: ...ing order of the spare parts The number expresses the installing process Before the installing make sure there is no dust and stain on the spare parts No marks by outside force on the surface of the s...

Страница 6: ...er to change magnification in operation Clean the objective frequently At first use the 10X objective to looking for image then change another one Turn the objective till hear the Kai Kai sound make s...

Страница 7: ...ert the binocular viewing head in the head of the body turn to the right place then fix up it by bolts 2 2 4 Install the eyepiece Fig 7 8 Insert the eyepiece in the eyepiece tube till end Fig 8 pictur...

Страница 8: ...he socket on microscope safely Make sure be connected 3 Plug the power cord into the power source Socket safely Make sure be connected Do use the supplied power cord all the time If lost or damaged se...

Страница 9: ...house and nearby parts will be very hot and will cause serious burns Please turn the main switch on O off pull up power plug and make sure the bulb the lamp house and periphery are all cool Then you...

Страница 10: ...9 STEINDORFF 3 Adjustment Operation NYMCS 603 3 1 Adjustment Set Diagram Fig 18 19 Fig 18...

Страница 11: ...10 STEINDORFF Fig 19...

Страница 12: ...just the View field Diaphragm and Aperture Diaphragm until the two Diaphragm open size is properly Then you can get clear image When in using you need to adjust simultaneously part observe until to th...

Страница 13: ...he interpupillar distance until the left and right fields of view coincide completely 3 3 6 Focusing Fig 25 1 Use the 10 objective focus to avoid the objective touch with the specimen you should raise...

Страница 14: ...Adjusting the Tension Adjustment Collar Fig 27 The tightness of the tension adjustment collar has adjusted before leaving factory if finding it s loosing the mechanical stage drop itself because of de...

Страница 15: ...Quadruple Nosepiece Objective Infinite plan Achromatic 4 10 20 choose and buy 40 Focus System Coaxial Coarse and Fine Focusing System Sensitivity and Graduation of Fine Focus 0 002mm Stage Double laye...

Страница 16: ...focus low resolution The objective damage Mend and correct the objective send to factory for overhauling The lens of the objective and eyepiece is moldy or have contaminant Do cleaning The opening of...

Страница 17: ...connect them exactly the installation of the bulb is wrong Install the bulb correctly The bulb burn out Change a new bulb 2 The bulb burn out in a high frequency Not use the specified lamp Use the re...

Отзывы: