4.  Double click the shortcut icon on  the desktop to  preview the images, please insure the camera has 

linked with the PC, and the driver has been installed  rightly, or there will come out an error hint: 

Cannot  preview  successfully.  Please  check your camera. 

 

Attention: 

  Please  install  all  the  three  setup  files  in  the  CD,  otherwise the  camera  may  cannot  work 

normally. 

  USB2.0 is a mandatory, not optional. This camera cannot work on the computers with USB1.1 ports. In 

order to ensure the stability of the connection with the USB2.0 interfaces, please insert the plug into 

those interfaces in the back panel the mainframe. 

 

 

 

 

 

 

 

 

 

  Please use  the  same USB2.0 port  every time. Using on  a  different USB2.0 port requires reinstalling 

or updating  the driver again to make the camera  work rightly.  If not, it will influence  the performance 

of the camera,  and cause the live image displays  drag, for there is another  system driver, and the 

system  set it as default driver. 

  Support  operation  system: Windows2000/XP/Vista 32bit, for 64bit PC processor,  please installs the 

32bit operation  system. 

  Please  unplug  the USB cable from the computer  immediately  after using. It will shorten  the lifetime 

of the camera,  sometimes  may cause repair service  if the camera  is plugged  in the computer  all the 

time and you do not shut down the computer  for a long time. 

 

2) Operation 

ScopeImage  9.0 is image-processing  software  professionally  designed  for digital microscope.  It allows  you 

to view, capture,  edit, record,  zoom, measure,  and process  microscope  images.  The main interface  of the 

software  is as follows: 

Содержание NYMCS-212

Страница 1: ...lar microscope NYMCS 212 Toensure the safety obtain optimum performance and to familiarize the use of this microscope it is recommended strongly that you study this manual thoroughly before using the...

Страница 2: ...NYMCS 212 is widely used in biological pathological bacteriological fields for purposes such as observation research academic demonstration clinic medical inspection It features more comfortable and...

Страница 3: ...198 3 Eyepiece Category Magnification Focal Length f mm Field of view mm Plan Eyepiece 10X 24 95 18 4 Total Magnification Eyepiece 10X 10X 10X 10X Objective 4X 10X 40X 100X Total 40X 100X 400X 1000X 5...

Страница 4: ...nosepiece has a precise frame which can locate objectives accurately and stably The digital binocular head can turn 360 degree freely with comforts and conveniences b Curved arm and coarse and fine f...

Страница 5: ...the nosepiece clockwise and mount other objectives in the sequence of low to high magnification E Condenser The condenser had been installed in the microscope before leaving factory F Collector The c...

Страница 6: ...operation In this way the specimen can come into focus rapidly just by turning the coarse focusing knob Note specimens of the same type means they are same in the thickness of slide cover slip and spe...

Страница 7: ...specimen Clean it up The position of the condenser is too low Raise it to proper position The image is defocused low resolution contrast There is no coverslip on the specimen Add coverslip The coversl...

Страница 8: ...cked position 2 Mechanical part PROBLEM CAUSE SOLUTION The image can focus when using high magnification objective The specimen is placed inversely The coverslip is too thick Turn inversely Use the st...

Страница 9: ...e digital Binocular head with PC by the USB cable the system will find the new device and then run the driver under the CD please follow the clue to finish the installation Attention please link the c...

Страница 10: ...ent USB2 0 port requires reinstalling or updating the driver again to make the camera work rightly If not it will influence the performance of the camera and cause the live image displays drag for the...

Страница 11: ...esigned for digital microscope It allows you to view capture edit record zoom measure and process microscope images Specific features included are as follows 1 Active image preview freezing preview fi...

Страница 12: ...n image zoom in zoom out 1 1 Attention When launching the software there will be several seconds displays as black preview please don t worry it is normal because the camera needs time to do some pret...

Отзывы: