STEIN300_Umsetzer_04_GB.doc / 03.2020
23
5.6
Connecting the transfer unit to the compressed air supply
WARNING
Only specialised STEIN Automation personnel should carry out the connection to
the compressed air supply!
Carry out installation work only in a pressureless state!
Carry out adjustment and setting work only while the safety fittings are mounted!
CAUTION
Route the connecting cable in the cable ducts provided in the STEIN transport
system.
ATTENTION
Observe the following operating pressures:
•
Maximum operating pressure:
6 bar
•
STEIN operating pressure:
4 bar
i
Festo GRLA
–
1/8-QS6 throttle check valves are used as connectors.
Type PUN-S hoses with an exterior diameter of 6 mm and wall thickness of 1 mm are
used, manufactured by: Festo.
Fig. 5-3:
Connect the transfer unit
to the compressed air
supply
1
Compressed air con-
nections
Connect the transfer unit to the compressed air supply using the two connections "S"
and "B".
Adjust the throttle check valves so that there is no uncontrolled rapid lifting
movement.
i
Connect "S" (black):
Cylinder moves up.
Connect "B" (blue):
Cylinder moves down.
1