D3X R/L / D3XS R/L
D3X R/L / D3XS R/L
Operator’s Manual
13
0
10
20
30
40
50
60
70
80
90
100
25.4
22
19
15.8
12.7
9.5
6.3
Plate thickness [mm]
H
o
ld
in
g
fo
rce
[%]
structural steel
heat-treatable steel
tool steel
0
10
20
30
40
50
60
70
80
90
100
0
0.1
0.2
0.3
0.4
0.5
0.6
Air gap [mm]
H
ol
di
ng
force
[
%
]
structural steel
heat-treatable steel
tool steel
Figure 8.
Holding force for a sample base in the function of surface thickness and air gap