11
Q-Logic™ Setup
Assign Direction Function
The
Assign Direction
Function allows you to set the axis direction. For example, if
you want to change
Forward
(X axis 0 to 100) to
Reverse
(X axis 0 to -100) or
Left
(Y
axis 0 to -100) to
Right
(Y axis 0 to 100). If you switch
Forward
to
Reverse
, the
system will automatically change
Reverse
to
Forward
. Same with
Left
and
Right
.
Parameters are measured in percent (%).
1.
Plug in the Q-Logic™ Handheld Programmer to the back of the Q-Logic™ ED (Enhanced
Display) or to the standalone joys�ck if SCIM (Specialty Control Input Module) is in use.
2.
Power on the chair.
3.
Select
Assign Direc�on
op�on with naviga�on's
Up
and
Down
bu�ons, then press the
Right
bu�on. Then follow screen instruc�ons.
4.
When done, press OK to save.
Switch Operations
The
Switch Operations
parameter sets the joystick to operate like a switch input,
removing its proportionality. When the joystick is moved out of neutral and more
than 50% of the operating range, it will activate at full throttle (100%) in the desired
direction.
Switch Operations
can be set ON or OFF.
1.
Plug in the Q-Logic™ Handheld Programmer to the back of the Q-Logic™ ED (Enhanced
Display) or to the standalone joys�ck if SCIM (Specialty Control Input Module) is in use.
2.
Power on the chair.
3.
Select
m: Switch Opera�ons
op�on with naviga�on's
Up
and
Down
bu�ons, then press
the
Right
bu�on. Then follow screen instruc�ons.
4.
When done, press
Le�
naviga�on bu�on to return to menu and save.
Joystick Calibration
Calibrating your joystick will set the range of motion for the axes or re-center it to
improve operation.
1.
Plug in the Q-Logic™ Handheld Programmer to the back of the Q-Logic™ ED (Enhanced
Display) or to the standalone joys�ck if SCIM (Specialty Control Input Module) is in use.
2.
Power on the chair.
3.
Select
Calibrate
op�on with naviga�on's
Up
and
Down
bu�on
4.
Programmer will prompt for a calibra�on with the joys�ck. Press the joys�ck forward and
move it either direc�on through two full revolu�ons.
5.
Calibra�on will be complete. Press
OK
to save. Exit Screen.
6.
Power cycle the chair.
CAUTION
Calibration MUST be done for the joystick. This a new
safety feature update included in the Q-Logic™
Programmers.