6 Operation
SMFS-U-CM-110
29 / 40
www.stauff.com
6.2 Starting the pumping process
Before switching on the machine, observe the general safety instructions
( Section 2.2, P. 8).
u
How to start the pumping process:
1. Switch the electrical main switch to “On”.
2. Wait until the display shows the start screen.
3. Start the filter trolley. To do this, press the
F1
button for 3 seconds.
ü
Depending on pumping height and viscosity, the mobile filter system
requires approx. 10 – 15 seconds to fill the filter elements
completely.
ü
The pumped medium is emitted on the outlet hose.
4.
CAUTION!
Risk of overheating
Never let the pump run dry for
longer than 2 – 3 minutes.
þ
The pump is running
6.3 Stopping pumping
u
How to stop pumping:
1. Stop the filter trolley. To do this, press the
F1
button for 3 seconds.
2. Switch the electrical main switch to “Off”.
þ
The machine is switched off.