Servicing should only be performed by a Qualified Service Technician
Results/Actions
•
If the ohm meter shows continuity (closed circuit) between the two outside pins (red wires) the ECO
switch has reset properly. If the Control System continues to lock out displaying
Energy Cut Out
(ECO)
on the UIM with continuity through the ECO present call the toll free support phone number
listed on the back cover of this manual for further assistance.
•
If the ohm meter shows no continuity (open circuit) between the two outside pins (red wires) and the
tank temperature is known to be at or below 100°F (38°C) - replace the Temperature Probe. Follow
the draining and filling instructions in the maintenance section of the Instruction Manual that came
with the water heater when replacing the Temperature Probe.
•
If the Control System continues to lock out displaying
Energy Cut Out (ECO)
on the UIM and the
water temperature inside the water heater is becoming excessive (at or above 201°F/94°C) check
water system piping; ensure heat is not being added by any other heating appliances or heat sources.
If all these tests have been performed and the Control System continues to lock out call the toll free
support phone number listed on the back cover of this manual for further assistance.