Owner’s Manual
10
11
Limitations of Liability
This warranty does not cover equipment damaged during ship-
ment or by misuse, accident, or negligence, or which has been
repaired or altered by others. Fireaway Inc. shall not under any
circumstances be liable for special or consequential damages
such as, but not limited to, damage or loss of property or
equipment, loss of profits or revenue, cost of capital, cost of
purchased or replacement goods, or claims by customers of
the original purchaser. Remedies set forth herein to the original
purchaser and all others shall not exceed the price of the
equipment supplied.
This warranty is exclusively and expressly in lieu of all other
warranties, whether expressed or implied, including warranty
of merchantability or fitness.
A DETAILED MANUAL MAY BE OBTAINED BY
CONTACTING THE MANUFACTURER.
Stat-X products are manufactured in the USA, and sold worldwide
(excluding the Federation of Russian States) exclusively by
Fireaway Inc. under license from R-Amtech International.
IMPORTANT NOTE
Shutdown of Air Handling and Power Supply
Upon pre-discharge detection of a fire, the ventilation system
for the protected volume must be shut-down to ensure the
required application density is delivered and that the fire is not
exacerbated by excessive air-flow. In addition, electrical power
to protected equipment must be shut down. This eliminates
the potential of re-ignition from a continuous short circuit.
Questions concerning the information presented in this manual
may be addressed to your authorized distributor or:
Fireaway Inc.
5852 Baker Road
Minnetonka, MN 55345
U.S.A.
Stat-X Installation Guidelines:
Aerosol generators should normally be mounted near ceiling height and angled to discharge down (under floor excepted)
toward the floor at an angle to ensure three-dimensional distribution of aerosol. Normal orientation from vertical is 15° - 30°.
Equipment
Equipment
Equipment
Equipment
Equipment
Ceiling
Ceiling
Wall
Wall
5-25º
Wall
Wall
Generators must never be positioned to discharge directly at each other and must be mounted in such a way as to have an unobstructed
discharge path, nor discharge at close range onto walls, ceiling, or equipment. Always check for obstructions in the path of the aerosol
discharge stream. Generators must be installed such that they cannot cause personnel injury upon activation.