MANUFACTURER menu
8
Saving changes
Save changes in the Rain Star 260 memory as follows:
-
see “saving changes” at the end of chapter 2
Once complete, the unit reboots and displays the message [
RE-START
] .
Cancelling changes
To cancel one or more changes, proceed as follows:
- see “cancelling changes” at the end of chapter 2
Once complete, the unit reboots and displays the message [
RE-START
] .
4.2
Parameters menu
Restarting by the 8 stage of the “accessing the manufacturer menu”
9
Pressing the _v_ key appears
[
VLV OUTL
]
Position of the valve for stopping work
10
Press the _v_ cursor key again to scroll through the following menu options
DISPLAY
DESCRIPTION
[
VLV YES
] o [
VLV NO
]
Valve for starting/stopping work: ACTIVE or INACTIVE.
[
WI O:OO
]
Waiting start Irrigation. The waiting time, in hours and minutes, can be set
by using the second function of the H key.
settori
If it is enabled, it permits the management of irrigation up to 8 different
speeds (sector irrigation). With more than 0 sectors, it is possibile to set
the maximum running time of irrigation.
[
NoSTP mO
] o [
STOP mO
]
No Stop at metres = 0. Rewinding continues until the signal from the End
Rewind sensor (the display may show negative metres).
Or, STOP at metres = 0. Rewinding stops when the machine indicates m.
of pipe = 0.
[
ALRM mhO
] or [
NoAL mhO
]
ALaRM in the case of lack of speed during rewinding (m/h = 0). The
alarm consists in the stopping of irrigation.
or, "No ALarm at m/h = 0". In this case, in the event of zero speed,
irrigation is not stopped but the machine remains on standby, indicating
[m/h ZERO].
[
OUTPUTS
]
Management of output sources: OU1, OU2 and OU3 (the last one appears
on RAIN V.03 boards and following models).
[
INPUTS
]
Management of input sources: IA1, IA2, IA3 and 4-20mA.
Reminder: the inlets IA1, IA2, IA3 are activated when they are switched to
ground through a signal or a contact.
[
MOT FLOW
]
Programming of sensitivity of activation of the flow valve motor in
relation to the load (type of valve), and programming of the maximum
time of activation of the motor itself.
[
MOT REG
]
Programming of sensitivity of activation of the regulating motor in
relation to the load, and of the operational settings for regulation
(duration of the regulating pulses), and programming of the maximum
time of activation of the motor itself.
[
SENSORS
]
By pressing _>_ a submenu appears with the following items:
SPeed SENSor applied to the irrigator: ROLLER or PINion with relative
settings and tables.
PreSsure sensor and its enabling (always enabled).
Sensor of ReWinding End, its enabling (always enabled) and the
opportunity to delay the cycle of irrigation end to let the loading of the
gun cart on the irrigator.
[
UM METRI
] or [
UM FEET
]
Units of Measurement: decimal METRIc system.or, Imperial (US)
measuring system.
[
LANG ITA
] , [
LANG FRA
] ,
[
LANG ENG
] or [
LANG GER
]
Language used for display.