Страница 1: ...INSTALLATION MANUAL CONSOLE MAGLINK 16T...

Страница 2: ...TI THEFT DETECTION CONTROL 42 UART LOGGER 42 SAFETY INSTRUCTIONS 42 CERTIFICATION 43 NOTIFICATION 47 REVISION INDEX DATE REVISION NUMBER DESCRIPTION Firmware revision 01 03 12 1 INITIAL RELEASE 15 05...

Страница 3: ...Maglink 16T rev 08 2015 07 ENG 3 30 07 15 8 GENERAL REVISION 11 X X...

Страница 4: ...of the equipment please refer to authorized people for maintenance or directly to the manufacturer Every tampering of the equipment relieves the manufacturer from any responsibility in front of compet...

Страница 5: ...Consumption 45 VA Working temperature 10 C 50 C Relative humidity From 5 to 95 non condensing Number of probes 16 Number of ON OFF sensors type XLR 16 Number of ON OFF reed sensors 6 only with Dipswit...

Страница 6: ...power switches on the electrical board panel Connect between board panel and the console using the appropriate connectors To connect driving force please use cable with 3 wires whose section is at le...

Страница 7: ...ART ITALIANA SRL Via Pola 6 20813 Bovisio Masciago MB ITALY MAGLINK 16T Serial nr xxxxxx Voltage 100 240V 50 60Hz Power 45VA FUSE 250V 1A L Working Temperature 10 C 40 C 0722 CEC 10 ATEX 025 Rev 3 II...

Страница 8: ...Maglink 16T rev 08 2015 07 ENG 8 MAIN COMPONENTS Power supply intrinsically safe barrier and main board...

Страница 9: ...are lost CN5 USB programming through Console_Config the prerequisite is to install appropriate driver before operating it is available on the download area of our website www startitaliana com CN4 RS...

Страница 10: ...2 Common 3 Normally closed CN9 Relay2 connector 1 Normally open 2 Common 3 Normally closed CN10 Inputs connector with Dipswitch 2 OFF 1 Input 6 2 Input 5 3 Input 4 4 Input 3 5 Input 2 antitheft remote...

Страница 11: ...ally open 2 Common 3 Normally closed CN19 Relay10 connector 1 Normally open 2 Common 3 Normally closed CN20 Relay11 connector 1 Normally open 2 Common 3 Normally closed CN21 Relay12 connector 1 Normal...

Страница 12: ...em connector SV2 Can bus connector SV3 TFT LCD panel connector DIP SWITCH SETTINGS S1 DIPSWITCH DIPSW1 OFF Console Config printer or DCD connection DIPSW1 ON Double Gilbarco protocol enabled for Site...

Страница 13: ...Maglink 16T rev 08 2015 07 ENG 13 PROBES CONNECTION CONNECTION TO EX PROOF PROBES MODEL XMT EXD AND TO RF RECEIVER FOR PROBES XMT SI RF Black MARR ONE BLU BIANC O Red MARR ONE BLU BIANC O...

Страница 14: ...RA SIP are installed and additional external barriers must be used since one barrier can supply up to 8 sensors only Connection cables colors From top to the bottom MR3 MR4 MR3 JH10 White GND MR4 JH10...

Страница 15: ...ase IFSF is enabled you have 1 minute timeout to write next command to MagLink if you wait more MagLink will enter in sync mode for IFSF board until it receives the complete sync command from IFSF sof...

Страница 16: ...rough Console_Config Double Gilbarco Protocol selectable via DIPSW1 CN3 RS232 Host connection refer to protocol list CN10 pin 6 input1 Connecting this pin to 12V a print command is generated this is u...

Страница 17: ...emulation DIALOG RETALIX DOMS ORPAK TOREX TLG SMITHS via serial port RS232 CN 3 ES DRESSER WAYNE SINP e TOPLEVEL TOKHEIM and DIALOG GILBARCO Passport Europe 9600 O71 DOMS 9600 E71 DIALOG 1200 N81 TOR...

Страница 18: ...ons be sure that DIPSW1 is OFF and DIPSW2 is OFF Printer can be connected to the console only after having finished the programming via Console_Config RS232 CX connection cable must be prepared on sit...

Страница 19: ...Connection must be done before the barriers if present Connections are made using two connectors on the top side of the board following these colors RED 12V BROWN RS485 B BLUE RS485 A WHITE GND 0V CO...

Страница 20: ...important please keep both files into the same folder in order to allow the language choice into ConsoleConfig software File label_maglink txt necessary for the correct functioning of multi language...

Страница 21: ...ensor referred to the S N selected on the channel Tot capacity Total capacity in liters gallons of the tank data provided by the tank strapping table Tank Height height of tanks in mm inches data prov...

Страница 22: ...nk status referred to the selected channel Product mm inc Product measure as detected by the probe of the selected channel Water mm inc Water measure as detected by the probe of the selected channel T...

Страница 23: ...aximum connection capacity on a single barrier Protocol type Protocol type enabled on the RS232 for management system connection Common available protocols are GILBARCO TOKHEIM PIGNONE TOPLEVEL Probe...

Страница 24: ...dedicated slot of the modem 3 Power on the console and wait some time to allow to the modem to connect to the GSM network When connected the GSM signal depth will appear on the display of the console...

Страница 25: ...g them with semicolon symbol Opening csv file with Note Pad it will be possible to read data as per the example shown below Otherwise it is possible to complete the table manually into program Note Pa...

Страница 26: ...ess of the probe that has to be associated to the first channel of the relay card Associated address 2 select the address of the probe that has to be associated to the second channel of the relay card...

Страница 27: ...probe Here is available the sensor number configured into the System Configuration at section Sensor number Select the sensor to be configured write the description that will appear on the display and...

Страница 28: ...Maglink 16T rev 08 2015 07 ENG 28 USER PANEL The user panel has 6 keys UP DOWN LEFT RIGHT RETURN ESC ENTER These are soft keys for each key pressed a beep is alerted...

Страница 29: ...Maglink 16T rev 08 2015 07 ENG 29...

Страница 30: ...he display there is a section with some rectangles showing the status of each tank Possible colors are White probe not answering Green no alarm Red grave alarm check the alarm page showing the typolog...

Страница 31: ...Ullage missing liters to reach maximum capacity of the tank Vol 15 L compensated volume at 15 C T C temperature measured by the sensor After few seconds the console shows the general page where the li...

Страница 32: ...rature H inc float height in inches Vol G volume in gallons Ullage missing gallons to reach maximum capacity of the tank Vol 15 G compensated volume at 15 C T C temperature measured by the sensor Pres...

Страница 33: ...is possible to print also bringing the 12V on terminal 6 of connector CN10 in case of remote printer management for a maximum distance of 15 meters Pressing ENTER key again the page of a single tank...

Страница 34: ...zation points Pressing LEFT or RIGHT keys historical daily tank graph are displayed Pressing UP and DOWN the day will be changed Probe Address probe address Capacity L total capacity of the tank Max H...

Страница 35: ...gnostics is displayed Pressing LEFT or RIGHT keys tank Liter gallons movement is displayed Delivery are displayed with white lines Leakage are displayed with red lines These data are retrieved from th...

Страница 36: ...into the SD card Alarm codes listed as follow 01 No Probe Link Probe not answering check address or cabling 02 High Product level is over value H but under value HH if different from 0 03 Low Product...

Страница 37: ...alarm occurs into the tank detail display the alarm field will change background color to show which is the alarm as shown below To clear an alarm it is enough to press ESC key Please pay attention to...

Страница 38: ...en activated otherwise it is GREEN when not activated Out of this page the relay functions are automatically set back to their normal working On the top of the page if the slave relay card is connecte...

Страница 39: ...T be sure to set DIPSW 2 to ON Up to 6 external alarms are available 12V is needed to activate the alarm Each alarm is represented by a green triangle which becomes red when the alarm occurs yellow if...

Страница 40: ...s could be NO LINK OK ALARM On the top of the display it is displayed the number of external sensors in alarm so in order to allow to have always the current status available If an alarm related to ON...

Страница 41: ...ic Leak detection is enabled To disable press UP DOWN ESC keys in sequence from the home page Leak detection procedure is based on an algorithm which monitors the tank It is mandatory that no external...

Страница 42: ...s again from the home page LEFT RIGHT ESC keys in sequence If managed through the input giving 12V on Input 2 antitheft is enabled giving 0V on Input 2 antitheft is disabled This functionality allows...

Страница 43: ...Maglink 16T rev 08 2015 07 ENG 43 CERTIFICATION...

Страница 44: ...Maglink 16T rev 08 2015 07 ENG 44...

Страница 45: ...Maglink 16T rev 08 2015 07 ENG 45...

Страница 46: ...Maglink 16T rev 08 2015 07 ENG 46...

Страница 47: ...Maglink 16T rev 08 2015 07 ENG 47 NOTIFICATION...

Страница 48: ...Maglink 16T rev 08 2015 07 ENG 48 START ITALIANA S r l Via Pola 6 20813 Bovisio Masciago MB Tel 39 0362 15 81 465 Fax 39 0362 15 81 464...