background image

2

   

These symbols are intended to alert the user to the presence of  

important operating and maintenance instructions in the manual 

accompanying the appliance.

RETAIN THIS MANUAL FOR FUTURE REFERENCE

NOTICE

Using any part other than genuine Star factory supplied parts relieves the  

manufacturer of all liability.

Star reserves the right to change specifications and product design without 

notice.  Such revisions do not entitle the buyer to corresponding changes,  

improvements, additions or replacements for previously purchased  

equipment.
Due to periodic changes in designs, methods, procedures, policies and  

regulations, the specifications contained in this sheet are subject  to change 

without notice.  While Star International Holdings Inc., Company exercises 

good faith efforts to provide information that is accurate, we are not 

responsible for errors or omissions in information provided or conclusions 

reached as a result of using the specifications.  By using the information 

provided, the user assumes all risks in connection with such use.

MAINTENANCE AND REPAIRS

Contact your local authorized service agent for service or required maintenance.  

 

Please record the model number, serial number, voltage and purchase date in the area below and have it ready when 

 

you call to ensure a faster service. 

 

SAFETY SYMBOL

Model No.

Serial No.

Voltage

Purchase Date

Business  

8:00 am to 4:30 p.m. Central Standard Time

 

Hours:

 

Telephone:

 

(314) 678-6303

Fax: 

 

(314) 781-2714

E-mail

  

[email protected]

                  

[email protected]

                 

[email protected]

Website:

        

www.star-mfg.com     

   

Service Help Desk

Authorized Service Agent Listing

Reference the listing provided with the unit

 

or

for an updated listing go to:

Website:

        

www.star-mfg.com    

 

E-mail

  

[email protected] 

Mailing Address:

    Star International Holdings Inc., Company

 

  10 Sunnen Drive 

  St. Louis, MO 63143  

  U.S.A  

Содержание 6015CBF

Страница 1: ...GAS CHARBROILER MODEL 6015CBF 6115RCBF 6024CBF 6124RCBF 6036CBF 6136RCBF 6048CBF 6148RCBF Installation and Operation Instructions 2M Z16002 Rev A 4 01 13 6136RCBF...

Страница 2: ...te we are not responsible for errors or omissions in information provided or conclusions reached as a result of using the specifications By using the information provided the user assumes all risks in...

Страница 3: ...on combustible construction must be 6 from back and sides TheinstallationoftheAppliancemustconformtotheNATIONALFUELGASCODE ANSI Z223 1 LATEST EDITION AND ALL LOCAL GAS COMPANY RULES AND REGULATIONS IN...

Страница 4: ...vicing and installation MANUAL SHUT OFF VALVE A manual shut off valve should be installed upstream from the manifold and within six feet of the charbroiler CONNECTING GAS SUPPLY LINE The gas inlet of...

Страница 5: ...air shutters on burners to give a soft blue flame having luminous tips then slowly increase openings to a point where the yellow tips disappear and a hard blue flame is obtained PLACING LAVA ROCK ON G...

Страница 6: ...hamber helps reduce flare ups Exercise care when using your broiler TILTING THE GRATE Raise or lower the grate to the next step by lifting the grate at the back of the charbroiler where the grate rest...

Страница 7: ...ners abrasive pads product identifiers and point of sale attachments or any other non food object tha comes in continuous contact with the roller coating This warranty does not apply to the non stick...

Страница 8: ...STAR MANUFACTURING INTERNATIONAL INC MODEL 6124RCBF 6024CBF SK2592 REV 6 4 12 1 2 4 6 5 7 18 19 11 9 10 14 16 17 20 28 29 30 31 32 33 34 27 26 25 24 23 21 22 15 11 12 13 8 3...

Страница 9: ...115 6015 H3 Z6068 6124 6024 H3 Z6069 6136 6036 H3 Z6070 6148 6048 5 G3 Z5945 2 SIDE PANEL ALL 6 G3 624302 1 SIDE LINER ASSEMBLY LEFT ALL 7 H3 Z6053 1 REAR PANEL 6115 6015 H3 Z6055 6124 6024 H3 Z6057 6...

Страница 10: ...K Z6050 6124 6024 2K Z6051 6136 6036 2K Z6052 6148 6048 24 2V 6671 1 2 3 4 PILOT VALVE ALL 15 INCH 24 INCH 36 INCH 48 INCH 25 2V Y8832 1 2 3 4 MANUAL VALVE ALL 15 INCH 24 INCH 36 INCH 48 INCH 26 2A Z3...

Страница 11: ...nclin e maximale Cette position permet la graisse de s couler du grille dans le bac graisse ce qui r duit les flamb es V rifier souvent les bacs eau et ajouter suffisamment d eau lorsque n cessaire Le...

Страница 12: ...e alors lentement ouvertures de l augmentation un point o les pointes jaunes disparaissent et une flamme bleue dure est obtenu PLA ANT ROC DE LA LAVE SUR LES FOYERS POUR 60 CBD S RIE Ouvrez les sacs d...

Страница 13: ...ip d orifices fixes et il est exp di de l usine pr t pour l utilisation au gaz naturel Pour changer au gaz propane installer les orifices de br leurs fournis dans le tiroir de la graisse tel que suit...

Страница 14: ...AREIL OU DE TOUT AUTRE APPAREIL TENIR TOUT COMBUSTIBLE L CART DE L APPAREIL Pour votre propre protection on vous recommande de faire installer cet appareil par une agence d installation qualifi e Ils...

Страница 15: ...ce manuel sont susceptibles de changer sans pr avis Quoique STAR Manufacturing exerce la bonne foi de fournir le renseignement correct STAR n est pas responsable pour les erreurs ou les omissions dan...

Страница 16: ...BARBECUE A GAZ MODELES 6015CBF 6115RCBF 6024CBF 6124RCBF 6036CBF 6136RCBF 6048CBF 6148RCBF 6136RCBF Instructions d installation et d op ration 2M Z16002 Rev 6 05 12...