Specifications
Model
Controls
Cooking Surface
BTU/HR
Weight
Dimensions
NAT
LP
Installed
Shipping
Width
Depth
Height
Manual Control, Lava Rock
6015CBF
1
300 sq in (1935 sq cm) 40,000
35,000
87 lbs (39.5kg)
95 lbs (43.2 kg)
15” (38.1 cm)
29.”
(65.4 cm)
15.5”
(48 cm)
6024CBF
2
480 sq in (3097 sq cm) 80,000
70,000
149 lbs (67.7 kg)
164 lbs (74.5 kg)
24” (61 cm)
6036CBF
3
720 sq in (4645 sq cm) 120,000 105,000 236 lbs (107.3 kg) 256 lbs (116.4 kg) 36” (91.4 cm)
6048CBF
4
960 sq in (6194 sq cm) 160,000 140,000 323 lbs (146.8 kg) 348 lbs (158.2 kg)
48” (122 cm)
Manual Control, Radiant
6115RCBF
1
300 sq in (1935 sq cm) 40,000
35,000
80 lbs (36.4 kg)
88 lbs (40 kg)
15” (38.1 cm)
29.”
(65.4 cm)
15.5”
(48 cm)
6124RCBF
2
480 sq in (3097 sq cm) 80,000
70,000
140 lbs (63.5 kg)
155 lbs (70.3 kg)
24” (61 cm)
6136RCBF
3
720 sq in (4645 sq cm) 120,000 105,000
220 lbs (100 kg)
240 lbs (109 kg)
36” (91.4 cm)
6148RCBF
4
960 sq in (6194 sq cm) 160,000 140,000
300 lbs (136 kg)
325 lbs (147.7 kg)
48” (122 cm)
GENERAL INSTALLATION DATA
This equipment is designed and sold for commercial use only by personnel trained and experienced
in its operation and is not sold for consumer use in and around the home nor for use directly by the
general public in food service locations.
The Star-Max™ series gas charbroiler is equipped for the type of gas indicated on the nameplate
mounted on the front panel. All units are shipped from the factory for use with natural gas. The unit
can easily be converted for use with propane gas: see propane gas.
-IMPORTANT-
INSTALL IN NON-COMBUSTIBLE LOCATIONS ONLY!
Clearance from non-combustible
construction must be 6" from back and sides.
The installation of the Appliance must conform to the NATIONAL FUEL GAS CODE
"ANSI Z223.1 - LATEST EDITION" AND ALL LOCAL GAS COMPANY RULES AND
REGULATIONS.
IN CANADA INSTALLATION SHALL BE IN ACCORDANCE WITH THE CURRENT
CAN/CGA-B149.1 NATURAL GAS INSTALLATION CODE OR CAN/CGA-B149.2
PROPANE INSTALLATION CODE AND LOCAL CODES WHERE APPLICABLE.
WARNING:
Improper installation, adjustment, alteration, service or maintenance
can cause property damage, injury or death. Read the installation, operating and
maintenance instructions thoroughly before installing or servicing the equipment.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance. Keep the appliance area clear and free from combustibles.
For your protection, we recommend a qualified installing agency install this appliance.
They should be familiar with gas installations and your local gas requirements. In any
case, your gas company should be called to approve the final installation. In addition,
there should be posted, in a prominent location, detailed instructions to be followed in
the event the operator smells gas. Obtain the instructions from the local gas supplier.
This appliance, its pressure regulator and its individual shutoff valve must be disconnected from
the gas supply piping system during any pressure testing of that system at test pressures in excess
of 1/2 PSIG. This appliance and its pressure regulator must be isolated from the gas supply piping
system by closing its individual manual shutoff valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than 1/2 PSIG.
CAUTION