background image

11

11. StarDental Limited Warranty

NuTorque

®

 Lite Control Box Unit, motor, hose and transformer are warranted against defects in material and workmanship 

for 3 years from date of purchase. Attachments - 1:1 AL, 1:1 AC, 16:1 AL, 1:5 Miniature Head AC, 1:5 Standard Head AC, 1:1 
Straight - are warranted against defects in material and workmanship for 12 months from date of purchase.
Please note the following additional terms of our warranty and return policy:

• Warranties cover manufacturing defects only and do not cover defects resulting from abuse, improper handling, cleaning, 

care or maintenance, normal wear and tear, or non-observance of operating, maintenance or installation instructions. 
Failure to use authorized parts or an authorized repair facility voids this warranty.

• Liability is limited to repair or replacement of the defective product at our sole discretion. All other liabilities, in particular 

liability for damages, including, without limitation, consequential or incidental damages are excluded.

• This warranty is in lieu of all other warranties, expressed or implied, including any implied warranties of merchantability or 

fitness for a particular purpose. No employee, representative or dealer is authorized to change this warranty in any way or 
to grant any other warranty.

Guidance and manufacturer's declaration - electromagnetic emissions
The NuTorque Lite is intended for use in the electromagnetic environment specified below. The customer or the user of the NuTorque Lite and manual should 

assure that it is used in such an environment. 

Emissions test

Emissions test

Electromagnetic environment - guidance

RF emissions CISPR11

Group 1

The NuTorque Lite uses RF energy only for its internal function. Therefore, its RF emissions are very low 

and are not likely to cause any interference in nearby electronic equipment.

RF emmissions CISPR11

class  B

The NuTorque Lite is suitable for use in all establishments, including domestic estabilishments and those 

directly connected to the public low-voltage power supply network that supply network that supplies 

buidings used for domestic purposes.

(*)This applies to the AC230V system.  For AC120V system, this is “Not applicable”.

Harmonic emissions 

IEC61000-3-2

class  A (*)

Voltage fluctuations/flicker 

emissions IEC61000-3-3

Complies (*)

12. Disposing Product

Disposal of equipment and accessories at the end of their service lives:

On the basis of EC Directive 2002/96/EC on Waste Electrical and Electronic Equipment, we would like to point out that 
this product is not subject to this Directive but may be disposed of in Europe in special waste management centres. 
Additional information can be obtained from the manufacturer or your dental supplier.
This product has to be recycled or disposed of in a way that is harmless for human beings and the environment; in doing 
so, the national valid regulations are to be observed.

Symbols

TUV Rhineland of North America is a Nationally Recognized Testing Laboratory (NRTL) in the  

United States and is accredited by the Standards Council of Canada to certify electro-medical 

products with Canadian National Standards

Consult Operation Instructions

Autoclavable up to Max. 135 °C. For detail, see Sterilization.

Type B applied part

Class II Equipment

Marking on the outside of equipment or equipment parts that include RF transmitters or that apply

RF electromagnetic energy for diagnosis or treatment

Follow the wast of electric and electronic equipment (WEEE) Directive (2002/96/EC) to dispose of  

the product and accessories  

Содержание NuTorque Lite

Страница 1: ...plains an instruction that should be observed for safety reasons Read this manual thoroughly before use and operate the device properly These instructions will show you how to operate the product safety and prevent danger to you or others They are classified by the degree and or severity of danger All contents relating to safety should be oberserved Cautions for handling and operation Please Read ...

Страница 2: ...the Speed Control Switch is adjusted within the allowable speed before use When you install Control Box or Motor DO NOT bend or twist the tubing or the cord No unnatural force is needed to do the installation Never use the AC adapter for anything other than the control box of this product Air Requirements dry free from contamination and oil Use a compressor with a dry air system Install an air fil...

Страница 3: ...Model 265290 120V and 265291 230V Rated input AC120V 50 60Hz 41VA AC230V 50 60Hz 41VA Output AC28V 1 3A Fuse AC120V FU100 T1 6A 250V FU101 T1 6A 250V AC230V FU100 T800mA 250V FU101 T800mA 250V Dimensions W100 x D178 x H64 mm Cord Length Unshielded App 5 0m AC Adaptor Handpiece Tubing Connector Handpiece Tubing Connector Power Switch Power Switch Power Switch AC Adapter Connector AC Adapter Connect...

Страница 4: ...e Motor Insert the Motor Cord Connector to the control box motor cord connector and tighten Fig 2 3 Connecting the AC adapter Insert the AC adapter plug into the AC adapter connector before plugging into wall outlet Fig 3 Never use the AC Adapter for anything other than the Control Box of this product 4 Connecting the Power Cord Insert the Power Cord into the Inlet of AC Adapter Fig 4 Plug cord in...

Страница 5: ...the Power Switch When you turn on the Power Switch lamps and speed indicator will be illuminated 2 Before using this system make sure to perform Foot Air Calibration function Refer to 6 1 Foot Air Calibration Power Switch Symbol Mark Function OFF ON 3 Push the Gear Ratio Select Key to indicate the speed of the attachment you will use Fig 7 Handpiece GearRatio Indicator Speed min 1 rpm 16 1 100 2 5...

Страница 6: ...wer limit of the air pressure to enable this function Perform this adjustment function after your purchase Once it is adjusted it will be memorized and there is no need to do this everytime NOTICE The displayed air pressure is only a guideline Measure the correct air pressure with an air gage The unit of displayed air pressure is kgf cm2 For other units refer below ex 0 1kgf cm2 0 01MPa 1 42psi 1 ...

Страница 7: ...table between 4 Press key until it beeps more than 3 seconds to set the brightness 5 Press key and key at the same time for more than 3 seconds once again When it beeps this setting is complete 3 Program Function It is possible to program two 2 presets Speed Gear Ratio Forward Reverse Direction Once set you can choose between presets by pressing the or the key To set the values for Speed Gear Rati...

Страница 8: ...t from motor 5 Disconnect motor from tubing by unscrewing coupler counter clockwise and pulling motor in the axial direction direction of E connector 6 Clean all external surfaces of attachment and motor using a small toothbrush and soft cloth with isopropyl alcohol 7 Dry thoroughly lubricate attachment 8 Sterilize Note To Prevent Damage To the Bur Use an Autoclavable Bur Block Attachments and bur...

Страница 9: ...d mount the new O Rings into the groove CAUTION Effects of deteriorated O Rings Air Water leak Air Water does not turn off Vibration Difficult to connect disconnect the handpiece 2 Replacing Bulb 1 Turn off the power 2 Loosen Motor cover and detach it from the motor Remove the old light bulb using a small screw driver Fig 12 13 3 Align and insert the connector of the new bulb into the socket hole ...

Страница 10: ...setting values are different from what used to be when turned off Turned off the motor while rotating Turn off after the Motor has stopped 9 Error Code Error Code Trouble Cause Check Remedy Overcurrent error In circuit Detected overcurrent in the circuit Contact your dealer Overcurrent error In software Detected overcurrent in the software Contact your dealer Retry Error Motor stopped by overload ...

Страница 11: ...orque Lite uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emmissions CISPR11 class B The NuTorque Lite is suitable for use in all establishments including domestic estabilishments and those directly connected to the public low voltage power supply network that supply network that s...

Страница 12: ...a Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobiles radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the locatio...

Страница 13: ...l information call 1 866 DTE INFO or visit our web site www dentalez com StarDental Division of DentalEZ Inc 1816 Colonial Village Lane Lancaster PA 17601 U S A Printed in Japan 2019 DentalEZ Inc Anyone wishing to return any DentalEZ Inc product to a DentalEZ facility MUST obtain the proper RETURN AUTHORIZATION NUMBER from the Customer Service Department The RA Number must appear clearly marked on...

Отзывы: