Cirius LM User Manual 2016
Page 22
User Name
Password
Access
admin
Password is defined uniquely
for Starmicrowave. This
password is supplied with the
IDU and can be changed when
logged in as “admin” via the
System Tab (see Section
2.1.12.4). Admin access level is
intended for use only by
Starmicrowave, not the end
customer/operator.
All functions are accessible
Tech
Default password is “tech”,
and can be changed by either
an “admin” or “tech” level
operator via the System tab
(see Section 2.1.13.4).
Operator has access to all
configuration options and
most status features. Some
diagnostic and status
features are hidden.
public
Default password is “public”,
and can be changed by any
level operator via the System
tab (see Section 2.1.13.4).
Operator has access to
status information only; no
terminal configuration
change is allowed
Table 11 User Authentication Levels
2.1.2. Main Status Bar
The Main Status Bar is always present at the top of the browser page, as shown in
Figure 12. It presents key status information for both the near-end and far-end
terminal. The Main Status Bar is dynamically updated approximately once every 5
seconds. Parameter definitions are as follows:
•
IDU Alarm: Green status indicates no IDU alarms; red indicates one or more
IDU alarm states are asserted. The IDU Alarm turns red when either the IDU
Hardware Status or IDU Software Status alarms become active (see Section
2.1.11).
•
ODU Alarm: Green status indicates no ODU alarms; red indicates one or
more alarm states are asserted. If 1+1 Protected Mode is supported, both
ODU 1 and ODU 2 alarms are displayed on the top status bar. The ODU
Alarm indicators turn red in the event of an ODU Tx Alarm, ODU Rx Alarm,
or a loss of IDU-to-ODU communications.
•
Demod Lock: Green status indicates demodulator is correctly locked onto
the received signal; red indicates unlocked state.
•
Tx Power: ODU RF transmit power, in dBm.
Содержание SM Cirius LM
Страница 21: ...Cirius LM User Manual 2016 Page 21 Figure 11 Web GUI Login Page ...
Страница 27: ...Cirius LM User Manual 2016 Page 27 Figure 14 Web GUI Modem Tab ...
Страница 29: ...Cirius LM User Manual 2016 Page 29 Figure 15 Web GUI Link Quality Tab ...
Страница 31: ...Cirius LM User Manual 2016 Page 31 Figure 16 Web GUI Telco Lines Tab shown T E4 ...
Страница 33: ...Cirius LM User Manual 2016 Page 33 Figure 17 Web GUI Ethernet Tab ...
Страница 35: ...Cirius LM User Manual 2016 Page 35 Figure 18 Web GUI ODU Tab ...
Страница 38: ...Cirius LM User Manual 2016 Page 38 Figure 20 Web GUI Event Log Tab ...
Страница 72: ...Cirius LM User Manual 2016 Page 72 ...
Страница 75: ...Cirius LM User Manual 2016 Page 75 ...