Cirius LM User Manual 2016
Page 19
1.3.7. DC Power
DC Power is provided to the terminal (IDU and ODU) via a two terminal connector.
The IDU accommodates -21 to -60 VDC. (Positive polarity versions are available.
Contact factory for more information.) For proper operation, connect DC power
interface to external power supply as follows:
•
Connect negative terminal of external supply to “-V” terminal
•
Connect positive terminal of external supply to “+V” terminal
1.3.8. ODU Interfaces
Each of the two N-Type ODU interface multiplexes the following signals to each of
the two interfaced ODUs:
•
DC power (-21 to -60V)
•
Transmit modulated IF signal (to ODU) at center frequency 350 MHz and
output power -2 dBm to +3 dBm
•
Receive modulated IF signal (from ODU) at center frequency 140 MHz with
input IF power between -7 dBm and -25 dBm
•
OOK ODU command signal at 5.5 MHz center frequency
•
OOK ODU telemetry signal at 10 MHz center frequency
Содержание SM Cirius LM
Страница 21: ...Cirius LM User Manual 2016 Page 21 Figure 11 Web GUI Login Page ...
Страница 27: ...Cirius LM User Manual 2016 Page 27 Figure 14 Web GUI Modem Tab ...
Страница 29: ...Cirius LM User Manual 2016 Page 29 Figure 15 Web GUI Link Quality Tab ...
Страница 31: ...Cirius LM User Manual 2016 Page 31 Figure 16 Web GUI Telco Lines Tab shown T E4 ...
Страница 33: ...Cirius LM User Manual 2016 Page 33 Figure 17 Web GUI Ethernet Tab ...
Страница 35: ...Cirius LM User Manual 2016 Page 35 Figure 18 Web GUI ODU Tab ...
Страница 38: ...Cirius LM User Manual 2016 Page 38 Figure 20 Web GUI Event Log Tab ...
Страница 72: ...Cirius LM User Manual 2016 Page 72 ...
Страница 75: ...Cirius LM User Manual 2016 Page 75 ...