To prepare the grounding cable of the SM CIRIUS AO, follow the steps below:
Step
Action
1
Cut the grounding cable
(A)
according to the distance between SM CIRIUS AO and
grounding bar.
2
Use the tool (item 4) to strip 1 cm from each end of the cable.
3
Slide the M8 terminal ring
(B)
over the wires at one end of the cable (that will be
connected to grounding bar) and crimp it using the tool (item 8).
4
Slide the heat shrinkable tube
(E)
over the cable.
Heat it over rear grounding ring body and down on to cable jacket using the tool (item
11).
The following picture shows the correct installation of the ring covered with tube:
5
Repeat steps 2 and 3 for the other end of the cable (that will be connected to SM
CIRIUS AO) using the M5 terminal ring
(C)
.
6
Use the tool (item 7) to tighten the M5 terminal ring of the grounding cable between the
two M5 nuts, as shown below:
End of procedure
Содержание SM Cirius AO
Страница 1: ...SM Cirius AO Point to point microwave IP radio with POE Installation Manual ...
Страница 3: ...7 2 APPENDIX B RMA RETURN MATERIAL AUTHORIZATION FORM 83 ...
Страница 6: ...SM Cirius AO Vertical view ...
Страница 24: ...Cabling implementation for traffic power ...
Страница 26: ...Cabling implementation for outband power ...
Страница 29: ...Cabling implementation for traffic outband power ...
Страница 63: ...Item Description A Thread adaptor B Cable holder C Seal 1 D Spacer ring E Cap ...
Страница 68: ...Procedure continued Step Action 4 Pass the optical cable through M25 gland components as shown below ...
Страница 69: ...Procedure continued Step Action 5 Connect the optical fiber cable to the SFP module as shown below ...
Страница 84: ... End of Document ...
Страница 85: ...Star Microwave Service Corporation 41458 Christy St Fremont CA 94538 Tel 1 510 498 7900 Fax 1 510 498 7901 ...