FOR 5 GPM OPERATION
For 5 gpm operation, select mode of operation with the
Throttle Control switch, either auto-idle-on or the auto-idle-
off position. Move the fl ow selector switch to the 5 gpm
position.
Note:
If operating both 5 gpm circuits move both fl ow selector
switches to the 5 gpm position. Both 5 gpm circuits are
independent from each other and can be operated on
its own.
When fi nished operating the tool, move one or both fl ow
selector switches to the OFF position.
FOR 10 GPM OPERATION
For 10 gpm operation, select mode of operation with the
Throttle Control Switch, either auto-idle-on or the auto-idle-
off position. Move both fl ow selector switches to the 10 gpm
position.
When fi nished operating the tool, move both fl ow selector
switches to the OFF position.
Note:
Either set of couplers can be used for the 10 gpm circuit,
but DO NOT use two separate tools when in the 10 gpm
operation mode.
COLD WEATHER STARTUP
1. Use the procedures described under "STARTUP" and
then follow the procedure below.
2. Hydraulic fl uids are thicker in cold weather. Therefore,
it is recommended that the engine be run at low idle long
enough to bring the fl uid temperature up to a minimum of
50°F/10°C.
3. If the tools and tool hoses are cold, it is recommended
to allow hydraulic fl uid to circulate through the tool hoses
until warm before using the tool.
SHUTDOWN
1. Ensure the fl ow selector switches are in the OFF posi-
tion (center position).
OPERATION
2. Unless already at idle the power unit should return to
idle. This may take a few seconds for the unit to react due
to a built-in program delay.
3. Allow the engine to idle for approximately one minute
and move the Ignition Switch to the OFF position.