Fig.12
Fig. 13
Fig.11
11
CLEARANCES TO COMBUSTIBLES
When using a tiled background and/or if you want to
bring the Stanley to standard counter top depth (i.e.
600mm) (24”) and leave no gaps at the back of the
cooker use the back filler piece which is 85mm (3.25
ins) deep. There is a flue pipe collar available which
surrounds the flue where it meets the wall, giving a
tidier finish to a tiled background. The back filler
piece and flue pipe collar are available to order.
(see fig.11a).
When bringing the kitchen units up to the sides of
the cooker hob, leave a 10mm (3/8”) gap between
the hob and adjacent units, this gap can be masked
by fitting a filler strip up to the Stanley leaving a
5mm gap (see fig. 12 & 13).
Leave minimum 52mm (2”) at rear of cooker to a
combustible material (see fig. 10). Leave minimum
26mm (1”) at rear of cooker to a non-combustible
material (see fig. 13).
If optional hob rear filler piece is to be fitted leave
87mm clearance between hob and work surface.
Fig.10
Fig.11a
If a filler strip is used to fill the gap between the units
and the side of the cooker then a 3mm gap must be
left. (see fig.12).