TECHNICAL DATA
FUELS:
N.G.
2nd Family, Natural Gas.(I.E., G.B., F.R., A.T., D.K.,E.S.,
F.I., I.T., P.T. & S.E)
L.P.G.
3rd Family, L.P.G.(I.E., G.B., B.E., F.R., E.S., & P.T.)
PRODUCT IDENTIFICATION NO:
63AQ8500
COUNTRY OF DESIGNATION:
I.E. & G.B., B.E., A.T., D.K., E.S., F.I., I.T., P.T., S.E., & F.R.
GAS TYPES:
N.G.
I
2H
, G20, 20 mbar & I
2E+
(F.R. Only)
L.P.G.
I
3P
, G31, 37 mbar
MAINS GAS PIPE:
N.G.
min.13mm
1
/
2
” BSP capable of 90 ft
3
/hr from a domestic
regulator.
L.P.G.
min. 13mm
1
/
2
” coated copper capable of 45 ft
3
/hr from an
approved L.P.G. - Propane regulator.
MAINS CURRENT:
230V - 240V, 50 Hz, A.C.
SUPPLY FUSE RATING:
3A
IONISATION CURRENT:
Minimum of 7µa.
IP PROTECTION DEGREE:
IP 20.
ELECTRICAL INPUT:
90 watts.
MAINS GAS PRESSURE:
N.G.
20 mbar
8” wg
GAS RATE:
2.3 m
3
/hr
81 ft.
3
/hr
L.P.G.
37 mbar
14” wg
FAN PRESSURE:
2.5 mbar
1” wg
MAXIMUM FLUE RESISTANCE:
0.8 mbar
0.32” wg
MANIFOLD PRESSURE:
N.G.
14.9 mbar
6” wg
L.P.G.
7 mbar
2.8” wg
GROSS INPUT:
24.9 kW
85,000 Btu/hr
NET INPUT:
N.G.
22.5 kW
76,811 Btu/hr
L.P.G.
23 kW
78,476 Btu/hr
BOILER OUTPUT:
17.6 kW
60,000 Btu/hr
SPACE HEATING:
3.67 kW
12,000 Btu/hr
BOILER CONSTRUCTION:
6mm & 4mm mild steel plate
BOILER TYPE:
B
23
MAX. BOILER WORKING PRESSURE:
1.9 Bar
27.3 P.S.I.
TEST PRESSURE OF BOILER:
2.7 Bar
40 P.S.I.
OPERATING TEMP. LIMIT IN BOILER:
96°C
205
o
F
BOILER CAPACITY:
9.1 Litres
2.5 Gallons
COOKER WEIGHT:
364kgs
800 lbs
Whilst the primary air and gas rate on this appliance have been set, combustion tests and the gas rating must
be undertaken, during commissioning and adjusted accordingly.
NOTE: This appliance shall be installed in accordance with the regulations in force and only used in a well
ventilated location. Read the technical instructions before installing this appliance. Read the user’s
instructions carefully before lighting this appliance.
As manufacturer’s and suppliers of cooking and heating appliances, we take every possible care to ensure, as reasonably practicable, that
these appliances are so designed and constructed as to meet the general safety requirement when properly used and installed.
United Kingdom
Ireland
*
Section 10 of the Consumer Protection Act.
*
Safety Health and Welfare at Work Act 1989.
*
Gas Safety (Installation and Use) Regulations 1998 (as amended)
*
S.I. 101 of 1992 (as amended).
*
Gas Appliance Safety Regulations (as amended).
*
S.I. 150 of 1995 (as amended).
*
Health and Safety at Work Act.
*
I.S. 813 (as amended).
IMPORTANT NOTICE: Any alteration to this appliance that is not approved in writing by Waterford Stanley, will render the guarantee void.
The installation must comply with the following:
The Building Regulations: Part J England & Wales., Part F Section 5 Scotland, Part L Northern Ireland and Part J Ireland.
B.S. 5449: Forced circulation hot water central heating system for domestic installation.
B.S. 7671: Requirements for Electrical Regulations.
Safety Document 635: The Electricity at Work Regulations.
I.S. 813 : Domestic Gas Installation
B.S. 7074 Part 1 & 2: Hot Water Supply.
B.S. 5440 Parts 1 & 2 Installation & maintenance of flues and
B.S. 4814: Sealed Systems.
ventilation
B.S. 6891 Gas Pipe Sizing
B.S. 7593 Treatment of water in domestic hot water systems
PAS 33 : 1999: Product Assessment Specification for Design,
Installation & Commissioning of Gas Fired Central Heating
Systems in Domestic Premises.